ProMTS 200 200AMP Synergic MIG/TIG/STICK

- 14 -

Straighten the wire end for approximately 20 cm and cut the wire in the straightened location.

Open the pressure control level which then opens the feed gear.

Thread the wire through the wire’s rear guide to the gun’s wire guide.

Close the feed gear and fasten it with the pressure control lever. Make sure that the wire runs in

the feed roll groove.

Adjust the compression pressure with the pressure control lever no higher than to the middle of

the scale. If the pressure is too high, it removes metal fragments from the wire surface and may

damage the wire. On the other hand, if the pressure is too low, the feed gear slips and the wire

does not run smoothly.

Press the welding gun trigger and wait for the wire to come out.

Close the reel housing cover.

NoteWhen driving the wire into the gun, do not point the gun at yourself or others.