PaxLock reset

The PaxLock holds address information for the bridge that it is bound to. This will cause

problems if the unit is to be used on another system.

The unit requires a hardware reset to clear its bridge information. This is achieved as follows:

1. Remove the inside handle from the door by loosening the securing grub screw.

2. Remove the cover by holding the bottom edge and pulling it towards you. The cover will lift

off at the top when the bottom edge is clear of the housing.

3. Locate the black reset button at the top of the unit.

4. Hold the button down and wake up the unit by pressing the front push button.

The unit will give a beep when the reset has started. You can now release the reset button.

5. The Red and Green LED's will both flash until the process has finished.

6. Refit the cover and handle.

7. You can now enrol the unit.

10,000

250

64

3584

2,405 Ghz

10

200

20 m

0 °C

+ 55 °C

IPX4

20 mm

5 mm

40 mm

324 mm

35 mm

160 mm

324 mm

100 mm

35 mm

60 mm

35 degrees

Operating temperature - Battery limits

Environment

Dimensions

Features

External use

Min

Width

Height

Max

Depth

Min

Max

Access levels

Time zones

Door open time

ACU's per Net2Air bridge - Recommended

Events stored in ACU with no server connection

Number of tokens

Specifications

No

Net2Air bridge per system
Net2Air wireless range

The declaration of conformity is available on request. Contact details are provided at:

http://paxton.info/596

Low

Reader/Keypad module (required space on door)

Total outside dimensions (includes handle clearance)

Battery type
Typical battery life

Vandal resistance

Read Range

Keyfob

Token

This product is not suitable for retail sale. All warranties are invalid if this product is not installed by a competent person.

2 years or 30,000 ops 3 years or 60,000 ops

Max = Low power mode

1 sec

60 secs

4 x AA Alkaline

The Net2 PaxLock is EN1634-1:2008 FD30 and FD60 Fire resistant.