Test points, Test points description – Vicor VI Chip PRM Evaluation Board User Manual

Page 7

Advertising
background image

UG:013

vicorpower.com

Applications Engineering: 800 927.9474

Page 7

Test Points Description

Each test point has a socket which accepts 0.015 – 0.025 inch diameter leads for easy
installation of solid wires and through-hole components. All the test points are brought
out to the edge of the board to allow for easy measurement and/or connection to the
user’s external circuitry. All test points are labeled and routed to the edge of the board.
Each test point is accompanied with an adjacent socket for adding a test lead or to
facilitate wiring to external circuitry.

Reference

Functional

Functional

Designator

Name

Description

TP30, +IN,

Input voltage test points provide kelvin connection to input pins of the PRM

®

.

TP33 -IN

Use these test points for measuring the input voltage of the PRM to avoid

error due to interconnect losses.

TP31, +OUT,

Output voltage test points provide kelvin connection to output pins of the PRM.

TP32 -OUT

Use these test points for measuring the output voltage of the PRM to avoid

error due to interconnect losses.

TP34,

TP21,

SGND

Signal Ground (SGND) test points are the ground reference for all control circuitry and

TP22

signal pins of the PRM.

TP28,

CS+,

TP29

CS-

Used to measure the output current of the PRM across shunt resistor R25.

TP35,

IM,

TP36

SG

Used to measure the output of current sense IC with reference to SGND.

SHARE/

TP10 CONTROL

Used to measure the SHARE/CONTROL NODE signal of the PRM with reference to

NODE

SGND test point.

TP11 AL

Used to measure the AL signal of the PRM with reference to SGND test point

in Adaptive Loop Operation.

TP12 TRIM

Used to measure the TRIM signal of the PRM with reference to SGND test point

in Adaptive Loop Operation.

TP13

VAUX

Used to measure the VAUX signal of the PRM with reference to SGND test point.

REF/

TP14

REF_EN

Used to measure the REF/REF_EN signal of the PRM with reference to SGND.

TP15 VT

Used to measure the VT signal when connected to VTM

®

TM pin with reference

to SGND in Adaptive Loop Operation.

TP16

ENABLE

Used to measure the ENABLE signal with reference to SGND.

TP17

VC

Used to measure the VC signal with reference to SGND.

TP18 IFB

Used to measure the IFB signal of the PRM with external constant current circuit

with reference to SGND in Remote Sense Operation.

TP43,

VREF

Used to measure the voltage reference signal of the error amplifier with reference

TP44

to SGND in Remote Sense Operation

TP19,

TP20

NC, NC

No connect. For internal use only.

TP37,

Can be used to inject the isolated signal of network analyzer for bode plot

TP38

measurement to measure the stability in Remote Sense Operation.

TP23,

VG,

Can be used to connect function generator to control the open drain

TP24

SG

MOSFET in ENABLE control.

TP39,

EXT AL,

Can be used to enable Adaptive Loop control using external source when

TP41

SG

AL control is selected using header P10 and jumper.

TP40,

EXT TRIM,

Can be used to enable TRIM control using external source when TRIM control

TP42

SG

is selected using header P11 and jumper.

Table 2.

Test points description

Advertising