Installation of carbon graphite bushings, Installation of foot – Viking Pump TSM710: KE-LQE 4076/4176 User Manual

Page 7

Advertising
background image

SECTION TSM 710

ISSUE

D

PAGE 7 OF 8

DaNger !

before opening any viking pump liquid

chamber (pumping chamber, reservoir,

relief valve adjusting cap fitting, etc.)

be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

2. That the driving means (motor, turbine,

engine, etc.) has been “locked out” or

made non-operational so that it cannot

be started while work is being done on

pump.

3. That you know what liquid the pump

has been handling and the precautions

necessary to safely handle the liquid.

Obtain a material safety data sheet

(MSDS) for the liquid to be sure these

precautions are understood.

failure to follow above listed

precautionary measures may result in

serious injury or death.

PreSSure reLief vaLve

iNSTruCTiONS

ThruST beariNg aDJuSTMeNT

See

figure 4 on page 3.

1. Loosen the two setscrews in the outer face of the

bearing housing and turn the thrust bearing assembly

clockwise until it can no longer be turned by hand. Back

off counterclockwise until the rotor shaft can be turned

by hand with a slight, noticeable drag.

2. For standard (.12 mm) end clearance, back off the thrust

bearing assembly 30 mm as measured on the outside

diameter of the bearing housing.

3. Tighten the two set screws with equal force against the

bracket. End clearances are now set and locked.

NOTe: Be sure the shaft can rotate freely by hand. If not, back

off additional length on outside diameter and check again.

If there is still some noticeable drag, see

“aSSeMbLy” on

page 5, reference notes under item 4 and 5.
4. High viscosity liquids require additional end clearances.

The amount of extra end clearance depends on

the viscosity of the liquid pumped. For specific

recommendations, consult your nearest authorized

Viking Pump distributor. Each 10 mm turn on the outside

diameter of the bearing housing is equivalent to an extra

end clearance of (.04 mm).

iNSTaLLaTiON Of CarbON

graPhiTe buShiNgS

When installing carbon graphite bushings, extreme care must

be taken to prevent breaking. Carbon graphite is a brittle

material and cracks easily. If cracked, the bushing will quickly

disintegrate. Using a lubricant on the bushing and the mating

part will help in installation. The additional precautions listed

below must be followed for proper installation:
1. A press must be used for installation.

2. Be certain the bushing is straight.

3. Do not stop the pressing operation until the bushing is in

the proper position; starting and stopping will result in a

cracked bushing.

4. Check the bushing for cracks after installation.

iNSTaLLaTiON Of fOOT

Series 4176 pumps come equipped with a removable

mounting foot. Removal of the foot is not normally required for

maintenance. In cases where the foot needs to be replaced

or is being added, use the following steps.
1. Ensure alignment pins are installed in the top of the foot

prior to assembly of the foot to the casing.

2. Match the foot to the casing by inserting pins into the

bottom of the casing.

3. Secure foot to casing using the socket head capscrews

and lock washers. Torque capscrews to 100-110 N•m.

MeChaNiCaL SeaL

figure 8

O-riNg

CaPSCreW

SeaL

PLaTe

SeaT

gaSKeT

STaTiONary

faCe

rOTaTiNg faCe

rOTaTiNg MeMber

ShafT

Advertising