845 1

ISSUE

E

PAGE 12 OF 13

IMPORTANT: In ordering parts for pressure relief valve, always

give model number and serial number of pump as it appears on

nameplate and name of part wanted When ordering springs,

be sure to give pressure setting desired

fIGURE 21

PRESSURE RELIEf VALVES

PRESSURE ADJUSTMENT

If a new spring is installed or if pressure setting of pressure

relief valve is to be changed from that which the factory has

set, the following instructions must be carefully followed

1. Carefully remove the valve cap, which covers adjusting

screw Loosen locknut, which locks adjusting screw

so pressure setting will not change during operation of

pump

2. Install a pressure gauge in discharge line for actual

operating adjustment

3. Turn adjusting screw in to increase pressure and out to

decrease pressure

4. With discharge line closed at a point beyond pressure

gauge, gauge will show maximum pressure valve will

allow while pump is in operation

LIST Of PARTS

1.

Valve Cap

6.

Valve Body

2.

Adjusting Screw

7.

Valve Spring

3.

Lock Nut

8.

Poppet

4.

Spring Guide

9.

Cap Gasket

5.

Bonnet

10. Bonnet Gasket

DANGER !

Before opening any Viking pump liquid

chamber (pumping chamber, reservoir,

relief valve adjusting cap fitting, etc.)

be sure:
1. That any pressure in the chamber has

been completely vented through the

suction or discharge lines or other

appropriate openings or connections.

2. That the driving means (motor, turbine,

engine, etc.) has been “locked out” or

made non-operational so that it cannot

be started while work is being done on

pump.

3. That you know what liquid the pump

has been handling and the precautions

necessary to safely handle the liquid.

Obtain a material safety data sheet

(MSDS) for the liquid to be sure these

precautions are understood.

failure to follow above listed

precautionary measures may result in

serious injury or death.

DANGER !

Before starting pump, be sure all drive

equipment guards are in place.
failure to properly mount guards may

result in serious injury or death.

Mark valve and head before disassembly to insure proper

reassembly
1. Remove valve cap
2. Measure and record length of extension of adjusting

screw Refer to

“A” on figure 21.

3. Loosen locknut and back out adjusting screw until spring

pressure is released

4. Remove bonnet, spring guide, spring and poppet from

valve body Clean and inspect all parts for wear or

damage and replace as necessary

ASSEMBLY: RELIEf VALVE

Reverse procedures outlined under Disassembly If valve is

removed for repairs, be sure to replace in original position

Relief valve adjusting screw cap must always point toward

suction side of pump If pump rotation is reversed, remove

relief valve and turn end for end

See figure 3 on page 3.

Also refer to

PUMP ROTATION on page 7.

DISASSEMBLY: RELIEf VALVE