Step 7, Installation instructions, Step 4 – Quoizel ER1814IS Emery User Manual

Page 3: Step 5, Step 6

Advertising
background image

3 OF 4

Outlet Box

Mounting Screw

Ceiling
Canopy

Mounting Ball

Socket

Socket Upper Collar

Shade

Steel Collar

Socket Collar
with Harp

STEP 7

:

a

Install correct Bulb referring to fixture markings and/or labels for maximum wattage.

.

INSTALLATION INSTRUCTIONS

STYLE NUMBER ER1814IS ER1814PN

:

,

STEP 4

:

*

(

)

.

.

.

(

)

(

)

.

(

)

(

).

.

.

Use Wire Connectors not supplied to connect the

wires

a

Connect the House Ground Wire to the Fixture Ground

Wire.

b

Connect the House White

or Ribbed

Wire to the

Fixture Supply Wire White or Ribbed Side .

c Connect the House Black or Red

Wire to the Fixture

Supply Wire Black or Smooth Side

d Wrap each connection with approved electrical tape and

carefully stuff all of the connected wires into the Outlet
Box

STEP 5

:

a

Place the Ceiling Canopy over the Mounting Screws and

thread Mounting Balls onto the Mounting Screws to secure
it. Hand tighten until snug.

.

STEP 6

:

a

Place the Socket Upper Collar

the Shade and the Steel

Collar over the Socket as shown. Thread the Socket
Collar with Harp onto the Socket and hand tighten until
snug to secure them

.

,

.

WHITE OR RIBBED

BLACK OR RED WIRE

(

)

FROM HOUSE

GROUND WIRE

GROUND WIRE

FROM HOUSE

FROM FIXTURE

WHITE OR RIBBED

FROM FIXTURE

FROM HOUSE

FROM FIXTURE

BLACK OR SMOOTH

Advertising