Address 10, Address 24, Address 233 – Chauvet INTIMIDATOR DMX-605A User Manual

Page 9

Advertising
background image

Operating Instructions

DMX-605A & DMX-610A User Manual

9

2005-11-16/16:16

1

2

3

4

5

6

7

8

9

10

ON

OFF

1

2

4

8

16

32

64

128

256

OPTION

If this is your first time addressing a fixture using the DMX-512 control protocol than I suggest jumping

to the Appendix Section and read the heading

“DMX Primer”. It

contains very useful information that

will help you understand its use.

Set the start address using the group of DIP switches located usually on bottom of the fixture. Each

dip switch has an associated value. Adding the value of each switch in the ON position will provide

the start address. Determining which switches to toggle ON given a specific start address can be

accomplished in the following manner. By subtracting the largest switch value possible from the

selected start address which does not cause a negative number.

E

XAMPLE

S

TARTING

A

DDRESS

Address 10

Pin # 4

= 8

Pin # 2

= 2

Total

= 10

Address 24

Pin # 5

= 16

Pin # 4

= 8

Total

= 24

Resolving address using
simple math.

Address 233

233

(128) = 105, Turn ON Dip

# 8
105

(64) = 41, Turn ON Dip #

7
41

(32) = 9, Turn ON Dip # 6

9

(8) = 1, Turn ON Dip # 4

1

(1) = 0, Turn ON Dip # 1


You will most likely use the first
available number which maybe
number 1. This number was
selected for example purposes.

D

IP

S

WITCH

(DMX

V

ALUE

)

1
2
3
4
5
6
7
8
9
10

1
2
4
8
16
32
64
128
256

1

2

3

4

5

6

7

8

9

10

ON

OFF

1

2

4

8

16

32

64

128

256

OPTION

Advertising