Dell PowerVault NX300 User Manual

Page 40

Advertising
background image

40

About Your System

Alert! Power

required exceeds

PSU wattage.

Check PSU and

system

configuration.

Alert!

Continuing

system boot

accepts the risk

that system may

power down

without warning.

The system configuration
of processor(s),
memory modules,
and expansion cards may
not be supported by the
power supplies.

If any system components
were just upgraded,
return the system to the
previous configuration.
If the system boots without
this warning, then the
replaced component(s) are
not supported with this
power supply. If Energy
Smart power supplies are
installed, replace them with
High Output power supplies
to use the components.
See "Power Supplies" on
page 88.

Alert! Redundant

memory disabled!

Memory

configuration

does not support

redundant

memory.

Memory Sparing or Memory
Mirroring was enabled in the
system setup program, but
the current configuration
does not support redundant
memory. A memory module
may be faulty.

Check the memory modules
for failure. See
"Troubleshooting System
Memory" on page 154.
Reset the memory setting,
if appropriate. See "Using
the System Setup Program
and UEFI Boot Manager" on
page 57.

Alert! System

fatal error

during previous

boot.

An error caused the system to
reboot.

Check other system
messages for additional
information for possible
causes.

Table 1-3.

System Messages (continued)

Message

Causes

Corrective Actions

book.book Page 40 Thursday, August 13, 2009 7:27 AM