Window Installation Instructions - Typical Subframe Installation Section
Subhead/Subjamb Prepara on and Installa on
Typically EFCO will send subjambs long for field fit. The sill
end of the subjambs may have some type of notch cut by
EFCO when required.
When the subjambs come pre‐notched at the sill end, all
length adjustment should be done to the head end.
All notching will be done in the field by the installer on
“Express Jobs”.
All anchorage clear holes, blocking, sealants, and perimeter
fasteners are not by EFCO.
Measure for the sub jamb lengths. See ver cal “X” and “Y”
dimensions as indicated in the figure.
Subtract the “Y” dimension from the “X” dimension.
Square cut the subjambs to this length from the head end
of the subjamb.
Install the subjambs plumb, shimming as necessary.
The subhead will typically be square cut the width of the
rough opening minus 1/2”.
Install the subhead using the subjambs as a guide.
Fasteners and shims are by the installer.
Cover all fastener heads with sealant to ensure water ght
seal. Tool the sealant around the fastener heads so that
the sealant makes contact with the face of the subframe.
Note: The sealing of the subhead and subjambs to the
condiƟon is criƟcal to the performance of the assembly and
will vary greatly based on the building condiƟon. The loca-
Ɵon of these seals will be shown on the shop drawings.
Shim; high impact
shims may be required
at some loca ons
Subhead
Subjamb
Subjamb closure
Sill condi on
Head condi on
Subsill