ISSPRO R6326 User Manual

ISSPRO Hardware

Advertising
background image

ISSPRO, INC. 2515 N.E. Riverside Way, Portland OR 97211

Telephone: (503) 288-4488 Š Toll Free: (800) 888-8065

FAX: (503) 249-2999

Form 411A (Rev B 9/17/03) Page 1 of 2

ISSPRO R6326 2-Level Temperature Switch




Order Information:

Type K Thermocouple

Date Code:

Deg. F lamp Output Trip Point

OR

Type J Thermocouple

Deg. F Relay Output Trip Point



General Information:

Operating Voltage: 10-16 VDC, Negative Ground Only

Relay Output: Normally open (N/O), Normally closed (N/C), and Common (COM)

Switch Point Hysteresis: Output turns off approximately 25°F below trip point



Maximum Current/Voltage Rating:

Relay Rating: 2 amps @ 24 VDC resistive

0.5 amp @ 24 VDC inductive (Coil Load)

Lamp Output: 0.5 amp max/12VDC

Reverse Voltage Protection: -400 VDC



Adjusting the Trip Points:

Experimentation is not advised. Trip points are set at the factory to custom settings. A
Pyrometer must be installed to adjust properly.



Connecting to an Existing System:

The unit can be connected to a thermocouple which is already installed for an analog
(needle type) pyrometer by installing a separate leadwire for this unit from the
thermocouple.

If the existing pyrometer is a digital type, a second leadwire is not necessary. Connect
this unit to they pyrometer leadwire connections.