INSTRUCTIONS FOR

BRAZE TYPE ACCESS VALVE

1. Remove seal cap and valve core

(which is loosely installed at the
factory) from valve before brazing.
Use valve core remover provided for
this purpose.

2. Thoroughly clean tubing; apply flux to

both tubing and valve and silver
braze in usual manner. On copper-to-
copper application, phos-free copper
braze may be used without flux.

3. Allow to cool.

4. Replace valve core and secure tightly

with valve core remover.

5. After servicing work is complete

replace seal cap.

Printed in USA
Part No. 609-308

INSTRUCCIONES PARA LA VALVULA DE

ACCESO DEL TIPO DE SOLDADURA

1. Remueva la tapa del sello y el núcleo

de la válvula (él que se instala
sueltamente en la fábrica) de la válvula
antes de soldar. Use el removedor del
núcleo de la válvula que se proporciona
para este fin.

2. Limpie cuidadosamente la tubería;

aplique fundente tanto a la tubería
como a la válvula y suelde con
soldadura de plata de la manera
normal. En las aplicaciones de cobre a
cobre se puede usar soldadura de
cobre sin fosfato y sin fundente.

3. Permita que se enfríe.

4. Vuelva a colocar el núcleo de la válvula

y asegúrelo apretadamente con el
removedor de núcleo de válvula.

5. Después de que el trabajo de servicio

se haya completado vuelva a colocar la
tapa del sello.

Impreso en Estados Unidos
Formularia 609-308