3 pumping off the collected fluid, 4 deflating and packing – Vetter Pneum. collection tubs 0.3 bar User Manual

Page 5

Advertising
background image

Seite 4/7

Drive the defective truck onto the collecting tub.

The walls of the pneumatic collecting tub must

remain free and must not be loaded in any way!

Open the pressure regulator and start inflation. Close the hand valve
when the operating pressure is reached.

4.3 Pumping off the collected fluid

To pump off the collected fluid, use a commercially available immer-
sion pump (comply with the resistance), e.g. item no.: 1520041600
dewatering pump. For complete vacuum withdrawal, if necessary the
suction nozzle (Item no.: 1700014701) can be used in combination
with a Vetter aspirator.

4.4 Deflating and Packing

The deflation of the support frame happens over the inflation connec-
tion. To deflate the tub, close the air source (compressed air cylinder,
etc.) and disconnect the pressure reducer. Screw the cap off of the fil-
ling connection in the counter-clockwise direction. The deflation valve
is opened by pressing-in and turning the pin (1) counter clockwise.

1

Pin before locking

Pressing-in + turning

Valve open

Advertising