DQ TE SERIES

DQ TE Cooling System Typical Installation

• Keep line sets as short as possible.

• Excessive number of turns will cause

refrigerant flow problems. This could
cause early compressor failure. Suction
line accumulators are recommended.
Required if working lower than the
normal 55-65° operating range from
wine cellar.

• Drain line must always flow downhill to

drain or pump

• The system is controlled by a pump down

control system. There is no control wiring
between thermostat and condensing unit

• The line connections at Fan Coil and

Condensing Unit may not be the same as
the required line sizes

• Standard line sets should be 50’ or less.

Extended runs may require larger line
sizes and 3oz. oil must be added for
every 10’ over 35’.

(;7(5,25

9$325%$55,(5

,168/$7,21ದ

525%(77(5

,17(5,25

(;7(5,25

9$325%$55,(5

,168/$7,21ದ

525%(77(5

,17(5,25

Wall Construction

Ceiling Construction