3 description of the dip switches s1, Dip switches     s1/1-s1/4, Dip switches     s1/5 – Metalfab SEW Eurodrive MOVIMOT MM..C User Manual

Page 53: Description of the dip switches s1

Advertising
background image

Operating Instructions – MOVIMOT® MM03C - MM3XC

53

7

Description of the DIP switches S1

Startup of Standard Design

7.3

Description of the DIP switches S1

DIP switches
S1/1-S1/4

Selection of RS-485 address of MOVIMOT

®

via binary coding

Depending on the control of MOVIMOT

®

, different addresses must be set:

DIP switches
S1/5

Motor protection activated or deactivated

If the MOVIMOT

®

inverter is mounted close to the motor (with option P2.A or in the

field distributor), the motor protection must be deactivated.

To ensure motor protection after all, a TH (bimetallic thermostat) must be used. In
this case, the TH opens the sensor circuit after reaching the nominal response tem-
perature (see the "Startup with field distributor" section in the "Drive System for De-
centralized Installation" system manual).

Decimal
Address

0

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

S1/1

X

X

X

X

X

X

X

X

S1/2

X

X

X

X

X

X

X

X

S1/3

X

X

X

X

X

X

X

X

S1/4

X

X

X

X

X

X

X

X

X

= ON

=

OFF

Control

RS-485 address

Binary control (terminal operation)

0

Via external AS-i binary slave (MLK11A)

0

Via keypad (MLG.., MBG..)

1

Via fieldbus interface (MF..)

1

Via fieldbus interface with integrated small control system (MQ..)

1 to 15

Via RS-485 master

1 to 15

0

0

I