7 peak hold function – Industrial Data Systems IDS 440 User Manual

Page 24

Advertising
background image

IDS440 Users Manual version 4.2

Built In Application Programs

20

enter a new value and then press the ENTER key. The next sequence number printed

will be the entered value +1.

Notes

• The ID file maintenance functions are password level 1 protected. If a password has

been configured (function 64) the operator will be prompted for the password before

the file maintenance menu is displayed.

• ID memory is cleared to zero at power up unless parameter 41 (battery back up

enable) is set to 1.


# 7 Peak Hold Function

The peak hold register maintains the peak weight detected by the weight indicator.

Enable Peak Hold

Access configuration parameter 75. Enter a 1 to enable peak hold, enter a 0 to disable

peak hold.

Clear Peak Hold Register

Press the CLEAR key to reset the peak hold register to 0.
Use the Scale Basic built in function Clear Peak [143] to reset the peak hold register.

Display Peak Weight

Use the GROSS/NET key to scroll thru the display options as follows:

Initial mode:

Display gross weight.

Gross LED on.

First GROSS/NET press: Display net weight.

Net LED on.

Next GROSS/NET press: Display gross peak weight. Gross LED flashing.

Next GROSS/NET press: Display net peak weight.

Net LED flashing.

Next GROSS/NET press: Display gross weight.

Gross LED on.

Etc.

Print Peak Weight

Use function 65 (Configure Print Formats) to format the print output using:

Print Item 19:

print Gross Peak weight.

Print Item 20:

print Net Peak weight.

Advertising