3.4 CONFIGURATION OF WEIGHING APPLICATION OPTIONS.

If you are using one of the weighing 'SPECIAL APPLICATION' modes then
the following must be configured

:


Section 3.4.1

SELECT SCALE METER TYPE

.

Section 3.4.2

CONFIGURE SCALE UNITS.

If pulse input is being used then also configure:


Section 3.4.3

DECIMAL POSITION

.

Section 3.4.4

COUNT/PULSE FACTOR

.

If you want to use the

AUTO AXLE WEIGH

( Mode 8 ) then you must

configure the following to fit your particular application:

Section 3.4.5

TRIP LEVEL

Section 3.4.6

TIMEOUT TIME

Section 3.4.7

SETTLE TIME


REMEMBER:

Return the thumbwheel switch to the correct mode position after
configuration.
The 'SPECIAL APPLICATION' modes are selected by IDS 160 by reading the
thumbwheel switch on power up.


THUM.

POS. APPLICATION MODE


0 BASIC PRINTER MODE.

1 PRINT WEIGHT ONLY.
2 PRINT WEIGHTS WITH GROSS, AND TARE LABELS.
3 GROSS, TARE, NET PRINTING.
4 PRINT AND TOTAL.
5 PRINT, SUBTOTAL, AND TOTAL.
6 PRINT AND TOTAL ( AXLE WEIGH ).
7 WEIGH-IN, WEIGH-OUT.
8 AUTO AXLE WEIGH.


If position 0 (BASIC MODE) is used then ignore section 3.4. The section
3.4 configurations have no effect in BASIC MODE.



REMEMBER:

Return the thumbwheel switch to the correct mode position

after configuration