KEYENCE LJ-V7000 Series User Manual
Page 82
82
LJ-V7000_COM_RM_E
• Terminal settings
<Tolerance upper/lower limit>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
, 1F:Program NO.15)
Category:06h, Item:0Eh (upper limit), 0Fh (lower limit)
Target1:00h~0Fh (OUT1~16) Target2~4:00h
byte
Setting Data
0
Tolerance upper/lower limit value: 0.01μm unit.
Sined 32-bit integer.
1
2
* Display range lower limit for the minimum display
unit Tolerance upper/lower limit value display
range upper limit for the minimum display unit
3
<Hysteresis>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
, 1F:Program NO.15)
Category:06h, Item:10h
Target1:00h~0Fh (OUT1~16) Target2~4:00h
byte
Setting Data
0
Hysteresis: 0.01μm unit. Sined 32-bit integer.
*0
Hysteresis display range upper limit for the
minimum display unit
1
2
3
<ZERO>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
, 1F:Program NO.15)
Category:06h, Item:11h
Target1:00h~0Fh (OUT1~16) Target2~4:00h
byte
Setting Data
0
ZERO: 0:None, 1:ZERO1, 2:ZERO2
1
Reserved (fixed as 0)
2
Reserved (fixed as 0)
3
Reserved (fixed as 0)
<TIMING/RESET>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
, 1F:Program NO.15)
Category:06h, Item:12h
Target1:00h~0Fh (OUT1~16) Target2~4:00h
byte
Setting Data
0
TIMING/RESET: 0:None, 1:TIMING1/RESET1,
2:TIMING2/RESET2
1
Reserved (fixed as 0)
2
Reserved (fixed as 0)
3
Reserved (fixed as 0)
<Zero reference value>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
, 1F:Program NO.15)
Category:06h, Item:13h
Target1:00h~0Fh (OUT1~16) Target2~4:00h
byte
Setting Data
0
Zero reference value: 0.01μm unit. Sined 32-bit
integer.
*Display range lower limit for the minimum display
unit Zero reference value display range upper
limit for the minimum display unit
1
2
3
<Judgment output setting>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
, 1F:Program NO.15)
Category:07h, Item:01h
Target1:00h~0Bh (OUT_PIN1~12) Target2~4:00h
byte
Setting Data
0
Setting method: 0:No setting, 1:AND, 2:OR
1
Reserved (fixed as 0)
2
Reserved (fixed as 0)
3
Reserved (fixed as 0)
4
OUT1 judgment result: 0:Not specified, 2:HI, 4:GO, 8:LO
5
OUT2 judgment result: 0:Not specified, 2:HI, 4:GO, 8:LO
~
~
21
OUT16 judgment result: 0:Not specified, 2:HI, 4:GO, 8:LO
* The judgment result can be specified by bits with logical
OR. When HI and GO are both specified, the
measurement result value is “6”.
<Analog output target OUT>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
, 1F:Program NO.15)
Category:07h, Item:02h
Target1:00h (CH1), 01h (CH2) Target2~4:00h
byte
Setting Data
0
Target OUT: 0:OUT1, 1:OUT2
15:OUT16,
255:none
1
Reserved (fixed as 0)
2
Reserved (fixed as 0)
3
Reserved (fixed as 0)
<Analog output scaling>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
, 1F:Program NO.15)
Category:07h, Item:03h
Target1:00h (CH1), 01h (CH2) Target2~4:00h
byte
Setting Data
0
OUT display value1: Sined 32-bit integer *1
1
2
3
4
Output voltage1: Sined 32-bit integer
-10.5V~10.5V (1mVunit)
5
6
7
8
OUT display value2: Sined 32-bit integer *1
9
10
11
12
Output voltage2: Sined 32-bit integer
-10.5V~10.5V (1mVunit)
13
14
15
* 1 setting range
Length (mm)…-999.999mm~999.999mm (0.01μm unit)
Area (mm
2
)…-9999.99mm
2
~9999.99mm
2
(0.00001mm
2
unit)
Angle (deg)…-9999.99deg~9999.99deg (0.001degunit)