GL-T11R-IM-E

Wiring Example

GL-R Series

This wiring example illustrates the case of the following settings.

• Interlock function: Used (Manual reset mode)
• EDM function: Used
• Muting function: Used

GL-S Series

Meaning of symbols

F1, F2 : Fuse
K3, K4 : External device (Magnet contactor, etc.)
S1

: Switch for reset (N.O.)

S2

: Switch for wait input (N.O.)

S3

: Switch for override (N.O.)

L1

: Muting lamp (Incandescent lamp or LED lamp)

P1, P2 : Muting device

(Photoelectric sensors with built-in amplifiers such as PZ (PNP
output), etc.)

M

: 3-phase motor

PLC

: For monitoring use. This is a NON-SAFETY RELATED system.

S2 and PLC are NON-SAFETY RELATED systems.

*1

No. 6 and No. 7 do not need to be wired when the SL-U2 is connected.

*2

If it is not necessary to perform error detection for K3 and K4 (when
EDM input is not used), use the shorting bar between No. 8 and No.
9.

*3

In the auto reset mode, use the shorting bar between No. 10 and No.
11. To release the error condition of a GL-R through the reset input,
connect a N.C. switch.

Point

For the GL-R Series, the functions are switched to different

functions according to the settings configured with the "Safety

Device Configurator" PC setting software. When the settings

are changed, check the wiring referring to the internal circuit

diagram in the previous section.

The total electric current supplied from each 24 V terminal of

the GL-T11R must be 95 mA or less.

Replacing the Relay Board

The relay used for the FSD of the GL-T11R can be replaced without rewir-
ing the connection terminal.

1

Prepare the relay board for the GL-T11R (OP-87682).

2

Turn off the power to the GL-T11R and all the devices connected to the
GL-T11R.

3

Loosen the two terminal replacement screws, and remove the relay
output terminal block.

4

Loosen the two relay board replacement screws and remove the cur-
rent relay board from the GL-T11R.

5

Install the new relay board in the GL-T11R and tighten the relay board
replacement screws. (Recommended tightening torque: 0.3 N•m)

6

Attach the relay output terminal block to the relay board and tighten the
terminal replacement screws. (Recommended tightening torque: 0.3
N•m)

7

Check the operation according to the checklist.

External Dimensions Diagram

K3

K3

F1

F2

K4

K3

K4

M

K4

Relay output terminal block

Name

No.

FSD1

1
2

FSD2

3
4

FE

5

0V

*1

6

24V (input)

*1

7

EDM input (24V)

*2

8

EDM input

*2

9

PLC

IN

P1

L1

S2
S3

P2

S1

Signal input/output terminal block

Name

No.

Reset input (24V)

*3

10

Reset input

*3

11

Interlock selection input (24V)

12

Interlock selection input

13

AUX output

14

Error output

15

Muting lamp output

16

Muting input 1

17

Muting input 2

18

Wait input

19

Override input

20

0V

21

Black

Black

Blue

Brown

Brown

Blue

K3

K3

F1

F2

K4

K3

K4

M

K4

Relay output terminal block

Name

No.

FSD1

1
2

FSD2

3
4

Not used

5

0V

*1

6

24V (input)

*1

7

EDM input (24V)

*2

8

EDM input

*2

9

Relay output terminal block

Relay board for the GL-T11R

2x

φ4.2

(112)

35.9

49.8

3.5

83.8

(100.7)

(16)

37

135

124

23

23

11

48

Advertising