Louisville Tin and Stove WOW253 User Manual

Page 20

Advertising
background image

Page 20

SERVICE MUST BE PERFORMED BY A
QUALIFIED SERVICE AGENCY.

A.)

Turn thermostat to “OFF” or lowest setting.

B.)

Allow heater to cool.

C.)

Turn off electric power to heater..

D.)

Turn gas supply valve to “OFF”.

E.)

Disconnect gas supply line from gas valve.

F.)

From outside, remove six (6) screws
securing back of outer cabinet to air in
take and exhaust flanges. (See Figure 5).

G.)

From inside, gently slide combustion tube
assembly forward and out of outer
cabinet. (See Figure 6).

H.)

Disconnect air pressure switch tubing from draft
inducer. See Figure 18-A.

I.)

Remove draft inducer. (See Figure 18-A).

J.)

Disconnect ignition cable and pressure
switch tubing from top of burner box.
(See Figure 16).

K.)

Remove screws securing collection box and
burner box flange to liner top, bottom, left side,
right side and back. (See Figure 19).

L.)

Pull combustion tube assembly forward
and out of the liner. (See Figure 20).

M.)

You can now inspect, clean or replace
tubular heat exchanger as needed. NOTE: If
combustion tube assembly is being replaced,
you must keep and use collection and burner
box from assembly being replaced.

N.)

Carefully check integrity of all gaskets (replace
as needed), then reinstall combustion tube
assembly by reversing Steps L - A.
Follow lighting instructions to put heater
in operation.

TO REMOVE COMBUSTION TUBE ASSEMBLY FOR

INSPECTION, CLEANING AND REPLACEMENT

FIGURE 16

IGNITOR

IGNITOR
CABLE

PRESSURE
S W I T C H
TUBING

BURNER
BOX

FIGURE 19

FIGURE 20

For WOW253 / WOW254

FIGURE 18-A (For WOW253 / WOW254)

TRANSFORMER

CIRCUIT
BOARD

JUNCTION BOX

AIR INTAKE

CIRCULATING
BLOWER #1

LINER

PRESSURE
SWITCH

DRAFT INDUCER

Advertising