MAINTENANCE

To guarantee trouble free operation of this system, the manufacturer suggests following these guidelines.
Most problems associated with unit failures are directly related to poor service and maintenance. Record
any maintenance or service performed on this equipment in the documentation section located at the end
of this manual.

General Maintenance

1. Hood filters must be maintained on a daily basis to ensure proper airflow and grease extraction.
2. All water connections must be verified for tightness and leak-free operation.
3.

The “Add Surfactant” indicating light will illuminate when the surfactant tank is empty. Surfactant
must be added immediately to guarantee proper cleaning of the hood plenum and duct
connection. .

Every 6 months

1. Clean all duct sensors in hood duct connections (if equipped).
2. Check all nozzles for proper and evenly distributed water flow. If nozzles are clogged, clean or

replace.

3. Check drain(s) on hood to verify there is no blockage. Improper drainage could cause hood leaks

or water to back up into trough and overflow onto appliances.

4. Inspect hood plenum and wipe down any areas not being cleaned by the self cleaning system.

There may be an area where the water spray does not directly contact the metal.

5. Inspect the surfactant pump for proper operation and ensure liquid level sensor in surfactant tank

is operational. Test by manually lowering the sensor to see if the “Add Surfactant” light
illuminates.

6. Fill surfactant tank with surfactant.
7. The main line strainer in the manifold must be cleaned.
8. Verify that system has proper water pressure and temperature per the labels on the unit.

Every 2 Years

1. Inspect condition of all wires and plumbing. Plumbing should be free of corrosion and wire

insulation must be in good condition.