Interlogix Concord 4 REV C Installation Manual User Manual

Page 8

Advertising
background image

8

Concord 4 Installation Guide

Num ber Nam e

Application

Alarm

Delay

Restoral

Supervisor
y

CS
report

Chim e
(level)

Active
(level)

19

Delayed
interior

Interior doors that initiate a delay
before going into alarm

1

Police

Interior

X

X

X

3

20

Delayed
interior

PIR motion sensors that initiate a
delay before going into alarm

1

Police

Standard

X

X

3

21

Local instant
interior

24-hour local alarm zone protecting
anything that opens and closes

Police

Instant

X

X

1, 2, 3

22

Local
delayed
interior

Same as group 21, plus activation
initiates a delay before going into
alarm

Police

Standard

X

X

1, 2, 3

23

Local instant
auxiliary

24-hour local alarm zone protecting
anything that opens and closes

3

Auxiliar
y

Instant

X

X

1, 2, 3

24

Local instant
auxiliary

24-hour local alarm zone protecting
anything that opens and closes,
sirens shut off at restoral

1

Auxiliar
y

Instant

X

X

1, 2, 3

25

Local
special
chime

Notify the user w hen a door is
opened, sounds emit from a local
annunciator

1

Special
chime

Instant

X

1, 2, 3

26

Fire

24-hour fire, rate-of-rise heat, and
smoke sensors

Fire

Instant

X

X

X

1, 2, 3

27

Output
module

Hardw ired output module (HOM)
lamp control or other customer
features

3

Silent

Instant

X

X

1, 2, 3

28

Output
module

HOM, PIR motion sensor, sound
sensor, or pressure mat

3

Silent

Instant

X

1, 2, 3

29

Auxiliary

Freeze sensor

Auxiliar
y

Instant

X

X

X

1, 2, 3

32

Output
module

HOM, PIR motion sensor, sound
sensor, or pressure mat

3

Silent

Instant

1, 2, 3

33

Siren

Wireless siren supervision

Silent

Instant

X

X

1, 2, 3

34

Gas

Carbon monoxide (CO) gas
detectors

3

Auxiliar
y

Instant

X

X

X

1, 2, 3

35

Local instant
police (day
zone)

Local alarm levels 1 and 2, report to
CS in level

3

Police

Instant

X

X

X (level 3

only)

1, 2, 3

38

Auxiliary

Water sensor

3

Auxiliar
y

Instant

X

X

X

1, 2, 3

1.

This group is not certified as a primary protection circuit for UL-listed systems and is for supplementary use only.

2.

Sound instant police siren if tw o or more sensors are tripped w ithin 4 minutes. Otherw ise sensors are follow ers to delayed se nsors. If
Alarm Verification is on, group 18 functions like group 17.

3.

This group has not been investigated by UL.

4.

This group is required for UL-listed residential fire alarm applications.