LOCATION 115 - ZONE TYPE 3 CHARACTERISTIC SELECT (3 segments, feature selection data)

Use "Zone Type Characteristic Selections" described in Location 111, page 35.


LOCATION 116 - ZONE TYPE 4 ALARM EVENT CODE (1 segment, numerical data)

Location 116 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen

from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number

programmed in this location will be sent as the tens digit. When using 4+2 the digit in location 116 should be from 1-

15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.

LOCATION 117 - ZONE TYPE 4 CHARACTERISTIC SELECT (3 segments, feature selection data)

Use "Zone Type Characteristic Selections" described in Location 111, page 35.


LOCATION 118 - ZONE TYPE 5 ALARM EVENT CODE (1 segment, numerical data)

Location 118 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen

from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number

programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 118 should be from 1-

15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.


LOCATION 119 - ZONE TYPE 5 CHARACTERISTIC SELECT (3 segments, feature selection data)

Use "Zone Type Characteristic Selections" described in Location 111, page 35.


LOCATION 120 - ZONE TYPE 6 ALARM EVENT CODE (1 segment, numerical data)

Location 120 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen

from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number

programmed in this location will be sent as the tens digit. When using 4+2 the digit in location 120 should be from 1-

15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.


LOCATION 121 - ZONE TYPE 6 CHARACTERISTIC SELECT (3 segments, feature selection data)

Use "Zone Type Characteristic Selections" described in Location 111, page 35.


LOCATION 122 - ZONE TYPE 7 ALARM EVENT CODE (1 segment, numerical data)

Location 122 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen

from the list on page 54.The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number

programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 122 should be from 1-

15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.


LOCATION 123 - ZONE TYPE 7 CHARACTERISTIC SELECT (3 segments, feature selection data)

Use "Zone Type Characteristic Selections" described in Location 111, page 35.


LOCATION 124 - ZONE TYPE 8 ALARM EVENT CODE (1 segment, numerical data)

Location 124 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen

from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number

programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 124 should be from 1-

15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.


LOCATION 125 - ZONE TYPE 8 CHARACTERISTIC SELECT (3 segments, feature selection data)

Use "Zone Type Characteristic Selections" described in Location 111, page 35.


LOCATION 126 - ZONE TYPE 9 ALARM EVENT CODE (1 segment, numerical data)

Location 126 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen

from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number

programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 126 should be from 1-

15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.

LOCATION 127 - ZONE TYPE 9 CHARACTERISTIC SELECT (3 segments, feature selection data)

Use "Zone Type Characteristic Selections" described in Location 111, page 35.

LOCATION 128 - ZONE TYPE 10 ALARM EVENT CODE (1 segment, numerical data)

Location 128 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen

from the list on page 54. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number

programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 128 should be from 1-

15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.