PK-0738 Rev E 06/01

The 3555 Series Bill Trap is a dry contact that draws no

power and is wireless compatible.

To install the unit, clean both the underside of the Bill Trap

and the bottom of the cash register drawer or tray with

alcohol. Adhere the Bill Trap to the appropriate surface

with the adhesive tape provided. Run the switch leads out

the back of the cash register drawer by drilling a 1/4" hole

and attaching the leads to a service loop. Or, the leads may

run over the top of the drawer, depending on the amount of

clearance.

Warning:

Do not overextend the lid by more than one inch. Doing

so may cause the Bill Trap to malfunction.

Form C

Voltage........30 V MAX

Current......0.25 A MAX

Power........3.0 W MAX

Cycles...........10,000,000

Special Instructions for Mounting the Bill Trap
on Steel

The performance of the Bill Trap may be adversely

affected if the unit is mounted on steel. For this reason,

two additonal strips of double-sided tape have been

included. If you experience difficulties when mounting

your Bill Trap on steel, apply these two pieces of double-

sided tape onto the existing tape prior to mounting.

Ordering Information

ELECTRICAL

COLOR

LEAD

PART NUMBER

LOOP TYPE

CONFIGURATION

CHOICES

TYPE

3555

Open or Closed

SPDT

Black

#22 gauge 6" wire

Bill Trap With Bill Inserted

(Black)
Common

Wiring Diagram

(White)
Closed when bill inserted
(Red)
Open when bill inserted

(Black) Common

(White) Closed when bill inserted

(Red) Open when bill inserted