3. Place the watch on a level surface facing any direction you want, and

press B to calibrate the first direction.

• When the calibration procedure is complete, the message

OK

appears

in the upper display area. This soon changes to

-2-

and the

magnetic north pointer flashes at the 6 o’clock position to indicate that
the watch is ready for the second direction.

4. Rotate the watch 180 degrees.
5. Press B again to calibrate the second direction.

• When the calibration procedure is complete, the message

OK

appears

in the upper display area. After a short while, the watch automatically
returns to the Digital Compass Mode screen.

Precautions about bidirectional calibration

• You can use any two opposing directions for bidirectional calibration. You

must, however, make sure that they are 180 degrees opposite each other.
Remember that if you perform the procedure incorrectly, you will get wrong
bearing sensor readings.

• Do not move the watch during the one or two seconds (from the point you

press B up to the point that

OK

appears in the upper display area) that

the calibration of each direction is in progress. If you do, the message

appears in the upper display area, which means you have to

restart the bidirectional calibration procedure from the beginning.

• The appearance of

during bidirectional calibration can also be

caused by local interference. If you suspect that this is the case, move to
another location and try the procedure again.

• You should perform bidirectional calibration in an environment that is the

same as that where you plan to be taking direction readings. If you plan to
take direction readings in an open field, for example, calibrate in an open
field.

To perform northerly calibration

1. While in the Digital Compass Mode, hold

down A until the upper display area
changes to show

-1-

, which indicates

the setting screen.

2. Press D to start the northerly calibration

procedure.

• At this time, the indicator (direction

N

)

appears in the upper display area.

3. Place the watch on a level surface, and position it so that its 12 o’clock

position points north (as measured with another compass).

4. Press B to start the calibration operation.

• When the calibration procedure is complete, the message

OK

appears

in the upper display area. After a short while, the watch automatically
returns to the Digital Compass Mode screen.

Changing the Barometric Pressure and Temperature
Units

Changing the barometric pressure units automatically restarts the barometric
pressure graph.

To change the Barometric Pressure and Temperature Units

1. Press C to enter the Barometer/

Thermometer Mode.

2. Hold down A until the message

OFF

appears (flashing), which indicates the
setting screen.

• A temperature value appears instead of

OFF

(factory calibration) if you

previously calibrated the temperature
sensor.

3. Press D to move the flashing in the sequence shown below.

Temperature

Calibration

Barometric

Pressure

Calibration

°C / °F

hPa[mb]/inHg

4. Press D to move the flashing to the unit setting you want to change

(

°

C/

°

F or hPa[mb]/inHg).

5. Press E or B to select the unit you want.
6. Press A to return to the Barometer/Thermometer Mode screen.

Calibrating the Temperature Sensor

The temperature sensor of this watch is calibrated at the factory before
shipment and further adjustment is normally not required. If you notice
serious errors in the temperature readings produced by the watch, you can
calibrate the sensor to correct the errors.

Important!
Incorrectly calibrating the temperature sensor can result in incorrect readings.
Carefully read the following before doing anything.

• Compare the readings produced by the watch with those of another

reliable and accurate thermometer.

• If adjustment is required, remove the watch from your wrist and wait for 20

or 30 minutes to give the temperature of the watch time to stabilize.

To calibrate the temperature

1. Press C to enter the Barometer/

Thermometer Mode.

2. Hold down A until the message

OFF

appears (flashing), which indicates the
setting screen.

• A temperature value appears instead of

OFF

(factory calibration) if you

previously calibrated the temperature
sensor.

3. Each press of E increases the displayed temperature by 0.1

°C (or 0.2°F)

while pressing B decreases it.

• Pressing B and E at the same time returns to the factory calibration

(

OFF

).

• The indicator TEMP ADJ on the display indicates that the temperature

value has been calibrated.

4. Press A to return to the Barometer/Thermometer Mode screen.

Calibrating the Barometric Pressure Sensor

The pressure sensor of this watch is calibrated at the factory before shipment
and further adjustment is normally not required. If you notice serious errors in
the barometric pressure readings produced by the watch, you can calibrate
the sensor to correct the errors.

Important!
Incorrectly calibrating the barometric pressure sensor can result in incorrect
readings. Before performing the calibration procedure, compare the readings
produced by the watch with those of another reliable and accurate barometer.

To calibrate the barometric pressure

1. Press C to enter the Barometer/

Thermometer Mode.

2. Hold down A until the message

OFF

appears (flashing), which indicates the
setting screen.

• A temperature value appears instead of

OFF

(factory calibration) if you

previously calibrated the temperature
sensor.

3. Press D to move the flashing to the barometric pressure calibration

setting.

• At this time,

OFF

or the barometric pressure value should be flashing

on the display.

4. Each press of E increases the displayed barometric pressure by 1 hPa/

mb (0.05 inHg), while pressing B decreases it.

• Pressing B and E at the same time returns to the factory calibration

(

OFF

).

5. Press A to return to the Barometer/Thermometer Mode screen.

To change the Altitude Units

1. Press E to enter the Altimeter Mode.
2. Hold down A until the display clears. After

four or five seconds, either

OFF

or the

current reference altitude value (if set) will
start to flash, which indicates the setting
screen.

3. Press D three times to move the flashing

to the altitude unit setting.

4. Press E or B to select the unit you want (m or ft).
5. Press A to return to the Altimeter Mode screen.

• Changing the altitude units automatically turns the altitude alarm off.

• Changing the altitude units automatically restarts the altitude graph.

• Performing the above procedure causes altitude values stored in

memory also to be converted to the unit you select.