Troubleshooting:

Ensure that all cables are well seated. Check that keyboard/mouse
cables are not swapped. Label and bundle the cables for each
computer to avoid confusion when connected to the StarView.

Symptom Possible causes Recommended solutions

No OSD screen

sNo power to StarView

sLoose monitor

connection
Monitor not multi-sync

sEstablish power by turning on

computers, wait, press left CTRL
keys several times.

sReconnect monitor

sUse multi-sync monitor

Keyboard error
on boot

sLoose keyboard

connection

sMake sure keyboard cables are

Well seated

Master/slave
does not work

sImproper

installation procedures

sMake sure slave’s CONSOLE is

connected to Master’s PC 1~ PC
8 port

sPress and hold the 1 and 2

push buttons to initiate K/M reset

sRemove any possible power

supply to the slave (unplug all
cables), before connecting it to
the Master

Keyboard
strokes shifted

sThe computer was in

shifted state when last
switched

sPress both SHIFT keys

The

á

and

â

keys do not
work in Manual
Scan

sAll PCs are off or only

one PC is turned on.
Scan mode works for
power-on computers only

sScan type is eye mark

selected but no PC is eye
mark selected in OSD.

sTurn computers on.

sPress any other key to abort

Manual Scan mode.

sSet proper Scan type in OSD

and determine which PCs are
eye mark selected, do it in OSD.

Auto Scan does
not switch PC
and StarView
beeps from
time to time and
red indicator
flashes

sAll PCs are off or only

one PC is turned on.
Scan mode works for
power-on computers only

sScan type is eye mark

selected but no power-up
PC is eye mark selected
in OSD.

sTurn on computers

sSet proper Scan Type in OSD

and determine which PCs are
eye mark selected, do it in OSD.

sPress left CTRL key twice to

abort Auto Scan mode.

sPress any front button to select

a PC, and Auto Scan stops.