Important, Chimney connection – Vogelzang VG820E (new as of 2013) User Manual

Page 5

Advertising
background image

5

REPAIR PARTS LIST - MODEL VG820E

AUTOMATIC WOOD BURNING CIRCULATOR

INTERIOR

16

IMPORTANT

*Size the chimney to the fl ue outlet on the
stove. (6" outlet = 6" I.D. chimney)
*Avoid using elbows except as necessary
(they reduce draft ).
*Make sure all horizontal runs of connec-
tor pipe go up hill (1/4" elevation for each
horizontal foot).

CHIMNEY CONNECTION

DO NOT CONNECT THIS UNIT TO A
CHIMNEY FLUE SERVING ANOTHER
APPLIANCE.
Two basic types of chimneys are approved
for use with solid fuel: Factory-built and ma-
sonry. Factory-built chimney must comply
with UL103HT standard.

Do not expect your stove or furnace to create
draft . Draft is not a function of the appliance.
Draft is purely a function of the chimney.
Modern stoves and furnaces are much more
air-tight and effi

cient than those of the

past and, therefore require greater draft . A
minimum of .05, measured in water column
(gauges to measure chimney draft are readily
available at stove shops and are economical
to purchase or rent) is required for proper
draft ing to prevent back-puffi

ng, smoke

spillage, and to maximize performance.

Chimneys perform two functions - one of
which is apparent: Th

e chimney provides

a means for exhausting smoke and fl ue
gases resulting from combustion of the fuel.
Secondarily, though, the chimney provides

Key

Part No.

Description

Qty.

1

67859

Weldment, Base

1

2

22030

Shield, Second Heat

(Included w/ 67859)

1

3

22110

Shield, Heat

(Included w/ 67859)

1

4

68619

Assy., Heat Jacket

1

5

88032

Gasket, Flue Collar

1

6

40246

Collar, Flue

1

7

22090

Curtain, Smoke

1

8

22171

Clip, Smoke Curtain

2

9

40075

Frame, Draft Damper

1

10

23476

Damper, Draft Control

1

11

25550

Pin, Draft Damper

1

12

83890

Clip, Push

1

13

40100

Liner, Front/Back

3

14

40076

Fire, Grate

2

15

40132

Retainer, Brick

2

16

89066

Firebrick (4.5” x 9” x 1.25”)

10

17

891940

Assy., Feed Door

(Complete)

1

-

40199

Feed Door -

Casting Only

-

18

88033

Rope Gasket, 3/8”

3.75 ft.

19

891941

Assy., Ash Door

(Complete)

1

-

40289

Ash Door -

Casting Only

-

20

88033

Rope Gasket, 3/8”

2.42 ft.

21

83872

Pin, Door -

Short

1

22

23441

Pin, Door -

Long

1

23

83102

Bolt, 1/4-20 x 1.25” CS, Slotted Hd.

2

24

40056

Wheel, Draft

2

25

83415

Nut, 1/4-20 Jam

2

26

25201

Shield, Flame

2

27

83250

Kep Nut, 1/4-20

4

28

40509

Handle, Door

2

29

89523

Handle, Drop Wood

1

30

22434

Latch, Door (2-Step)

1

31

83045

Washer, Flat

2

32

83273

Washer, Spacer

1

33

22108

Latch, Door

(Door Stop)

1

34

23474

Liner, Top

1

35

67444

Ash Pan

1

FIG. 6

Cathedral Ceiling - Chimney

Cap Mandatory

PIPE

FLOOR PROTECTOR

REFER TO CHIMNEY
MANUFACTURERS PARTS
AND INSTRUCTIONS

2 FT MIN.

10 FT.

3 FT.
MIN.

BAROMETRIC
DRAFT CONTROL
(OPTIONAL)

11 FT. MIN.

CHIMNEY CAP MANDATORY

DAMPER

FIG. 5

PIPE

FLOOR PROTECTOR

REFER TO CHIMNEY
MANUFACTURERS PARTS
AND INSTRUCTIONS

2 FT MIN.

10 FT.

3 FT.
MIN.

BAROMETRIC
DRAFT CONTROL
(OPTIONAL)

11 FT. MIN.

CHIMNEY CAP MANDATORY

DAMPER

"Draft " which allows oxygen to be continu-
ously introduced into the appliance, so that
proper combustion is possible. As of April 1,
1987, all heaters and furnaces manufactured
by United States Stove Company should be
installed using a factory built chimney that
meets the "Type HT" requirement of UL 103
(when a factory - built chimney is used).

Your smoke pipe should be assembled in
such a way that the male section (crimped
end) of the pipe faces down. Attach each
of the sections to one another with three
equidistant metal screws. Seal with furnace
cement.

IN ORDER TO MAINTAIN WARRANTY, COMPONENTS MUST

BE REPLACED USING ORIGINAL MANUFACTURERS PARTS

PURCHASED THROUGH YOUR DEALER OR DIRECTLY

FROM THE APPLIANCE MANUFACTURER.

USE OF THIRD PARTY COMPONENTS WILL VOID THE

WARRANTY.

Advertising