Table 4 — Accessories

PART NO.

DESCRIPTION

UNIT

HH01AD040
HH93AZ040

HH51AR001

Low-Voltage Control — Floneywell Deluxe Thermostat

Thermostat Subbase

All

Comfort Control Center (Use with FIFI01AD040)

HH07AT070
HH07AT074
HH93AZ076

Low-Voltage Control — Honeywell Thermostat

Thermostat Subbase (with Automatic Changeover)

HH01AD042

HH93AZ042

Low-Voltage Control — Honeywell Thermostat

Thermostat Subbase

HH01YA092
HH93YZ094

Low-Voltage Control — Grayson Thermostat

Thermostat Subbase

38GS900102

Indoor Fan Relay (Six HN61KJ210)

38GS900212

Low-Voltage Transformer (Six 38GS900091)

38HQ900011

Hot Shot — domestic water pre-heater

38UE900001

Chillermate refrigerant-to-water heat exchanger

38VH003,004,

045,005

32LT900301

Motormaster® Head Pressure Control Special field-installed fan motor HC42VE233 required

38VH002,003,004,

045,005

38GS900321

Liquid Line Filter-Drier (Six 38GS900332)

All

C

TUBING

PACKAGES

TUBING*

UNIT

Length

(ft)

Liquid

Suctionf

OD

(in )

Tube End

OD (in.)

OD

(in.)

Tube End,

OD (in.)

Evap

Cond

38LS958151

15

3/8

3/8

5/8

3/4t

5/8

38VH001

38LS958201

20

3/8

3/8

5/8

3/4t

5/8

38VH002

38LS958251

25

3/8

3/8

5/8

3/4t

5/8

38LS958301

30

5/16

3/8

5/8

3/4J

5/8

38LS958351

35

5/16

3/8

5/8

3/4i

5/8

38VH001

38LS958401

40

5/16

3/8

5/8

3/4i

5/8

38LS958501

50

1/4

3/8

5/8

3/4i

5/8

38LS934251

25

3/8

3/8

3/4

3/4

3/4

38LS934301

30

3/8

3/8

3/4

3/4

3/4

38LS934351

35

3/8

3/8

3/4

3/4

3/4

38VH002

38LS934401

40

3/8

3/8

3/4

3/4

3/4

38LS934501

50

3/8

3/8

3/4

3/4

3/4

38LS978151

15

3/8

3/8

7/8

3/4

3/4

38VH003

38LS978201

20

3/8

3/8

7/8

3/4

3/4

38VH004

38LS978251

25

3/8

3/8

7/8

3/4

3/4

38VH045

38LS978301

30

3/8

3/8

7/8

3/4

3/4

38VH005

38LS978351

35

3/8

3/8

7/8

3/4

3/4

38LS978401

40

3/8

3/8

7/8

3/4

3/4

(See Note 2)

38LS978501

50

3/8

3/8

7/8

3/4

3/4

*For maximum capacities, use suction line sizes recommended in

Table 3 If accessory tubing package is used on 38VH004,045,

005 units, a reduction in capacity can result Field-supplied

1-1/8 in suction line is recommended with all 28VFI coil
installations

fSuction line is insulated and has a 90 degree bend at one end

JFor 5/8-in evaporator connection, cut off 3/4-in end

NOTE Do not cut 3/8-in OD liquid lines to a length shorter than
10 feet Do not cut 5/16-or 1/4-in liquid line Do not cut 7/8-in
OD suction lines

Do not use damaged or contaminated tubing.

Always evacuate or purge evaporator coil and

tubing system. When purging, use field-supplied

refrigerant, not unit holding charge refrigerant.

When making tubing connections, be sure to pro­

vide clearance at unit for electrical connections.

REPLACE THE ACCURATER™ REFRIGER­
ANT CONTROL PISTON IN THE INDOOR
COIL, if required, before connecting refrigerant

lines. See Carrier Cooling System Optimization,
page 2.

CONNECT REFRIGERANT LINES to fittings on
condensing unit suction and liquid service valves

(Fig. 1). Unit Compatible Fittings permit mechani­
cal (quick connect) or sweat connections.

Models 38VH002,003,004,045,005 — When using

1-1/8 in. field-supplied suction line, remove suction

line adapter taped to compressor suction line. Sweat
connect refrigerant suction line to 1-1/8 in. end of

adapter. Be sure to provide a heat sink at the service
valve to prevent damage during sweating operation.

Connect 3/4-in. end of adapter to unit suction line
Compatible Fitting. Connect liquid refrigerant line
to unit. When a 7/8-in. field-supplied suction line
is used, provide a field-supplied 3/4-in. to 7/8-in.
suction line adapter. (Not necessary if 38LS acces­
sory tubing is used.)