Adjustment section, 1) adjust up and down limits, How and when to adjust the limits – Chamberlain 1200 User Manual

Page 28: Warning, Adjustment step 1, Adjust the up and down limits

Advertising
background image

Adjustment Step 1

Adjust the UP and DOWN Limits

28

Limit adjustment settings regulate the points at
which the door will

stop when moving up or down.

The door will

stop in the up direction if anything

interferes with door travel. The door will

reverse in

the

down direction if anything interferes with the

door travel (including binding or unbalanced doors).

To operate the opener, press the Door Control
button/push bar. Run the opener through a
complete travel cycle.

• Does the door open and close completely?

• Does the door stay closed and not reverse

unintentionally when fully closed?

If your door passes both of these tests, no limit
adjustments are necessary.

Left Side

Panel

INCREASE TRAVEL

DOWN

UP

Adjustment Label

Limit

Adjustment

Screws

INCREASE TRAVEL

DOWN

UP

Adjustment procedures are outlined below. Run the opener through a complete travel cycle after each
adjustment.

Repeated operation of the opener during adjustment procedures may cause the motor to overheat and
shut off. Simply wait 15 minutes and try again.

Read the procedures carefully before continuing on to Adjustment Step 2. Use a screwdriver to make limit
adjustments.

How and When to Adjust the Limits

If the door does not

open completely

but opens

at least five feet

Increase

up travel. Turn the UP limit adjustment

screw clockwise. One turn equals 2" of travel.

If door does not open at least 5 feet:

Adjust the UP (open) force as explained in
Adjustment Step 2.

If the door does not

close completely

Increase

down travel. Turn the DOWN limit

adjustment screw counterclockwise. One turn
equals 2" of travel.

If door still won't close completely, try lengthening
the door arm. (See page 26.)

If you have adjusted the door arm to the maximum
length and the door still will not close completely,
lower the header bracket. See Installation Step 1,
pages 12 and 13.

If the opener

reverses in fully closed position

Decrease

down travel. Turn the DOWN limit

adjustment screw clockwise. One turn equals 2"
of travel.

If the door

reverses when closing and

there is no visible interference to travel cycle

If the opener lights are flashing, the Safety Reversing
Sensor is obstructed. Remove the obstruction.

Test the door for binding: Pull the manual release
handle. Manually open and close the door. If the door
is binding, call for garage door service. If the door is
not binding or unbalanced, adjust the DOWN (close)
force. See Adjustment Step 2.

Adjustment Section: Pages 28 – 30

Improper adjustment of the travel limits will
interfere with the proper operation of the safety
reverse system.

The door might not reverse

when required and could seriously injure or kill
someone under it. Test the safety reverse
system following all adjustments to the travel
limits. See page 30.

WARNING

Advertising