Defiant woodburning stove, Fireplace installations, Above the fireplace – Vermont Casting 1945 User Manual

Page 8

Advertising
background image

8

Defiant Woodburning Stove

30001693

Without a thimble, a suitable length of chimney con-
nector can be extended through the breech to the inner
face of the flue liner, and cemented securely in place.
Additional pieces of connector are then attached with
sheet metal screws.

Fireplace Installations

The chimney connector may be connected to the
chimney above the fireplace opening or through the
fireplace.

Above the Fireplace

The Defiant may be connected to a chimney above
a fireplace opening. (Fig. 8) In such installations, the
stove is positioned on the hearth in front of the fireplace
and the chimney connector rises from the stove top and
then angles ninety degrees back into the chimney. The
chimney liner should extend to the point at which the
chimney connector enters the chimney.

ST244

Plymouth

fplc over mantel

12/99

• • • • • • •

*

*

Check These

Clearances

Mantel

ST244a

Fig. 8 In this installation, the chimney connector attaches to
the chimney above the fireplace opening.

Seal

This Off

ST243

thinble connection

12/13/99 djt

Thimble Sleeve

Chimney Connector

Flue

Keep

sleeve

end flush

with flue

tile

ST243

Fig. 7 The thimble, made of either ceramic or metal, must be
cemented securely in place.

A special piece called the “thimble sleeve,” slightly
smaller in diameter than standard connectors and
most thimbles, will facilitate the removal of the chimney
connector system for inspection and cleaning. (fig. 7)
Thimble sleeves should be available from your local
dealer.
To install a thimble sleeve, slide it into the breech until
it is flush with the inner flue wall. Do not extend it into
the actual flue passage, as this could interfere with the
draft.
The thimble sleeve should protrude 1-2” (25-50 mm)
into the room. Use furnace cement and thin gasketing
to seal the sleeve in place in the thimble. Secure the
chimney connector to the outer end of the sleeve with
sheet metal screws.

ST492

Defiant

freestanding

installation

11/00

Chimney

Elbow

Slip Pipe

Standard

Connector

Oval to

Round Adapter

Flue Collar

Thimble

Flue In-

ner

Flue

ST492

Fig. 6 An exploded view of the chimney connection in a free-
standing masonry installation.

If the chimney connector in your installation enters the
chimney above a fireplace, follow all the guidelines
mentioned above for freestanding installations. In addi-
tion, give special consideration to the following points:

Check the clearance between the stove and the
chimney connector, and any combustible trim or
the mantel.

Check the clearance between the chimney con-
nector and the ceiling. The clearance should be at
least 24” (610 mm).

The fireplace damper must be sealed to prevent
room air from escaping up the flue. However, it
must be possible to re-open the damper to inspect
or clean the chimney.