VI. PERIODIC PREVENTATIVE MAINTENANCE

NOTE: Periodic inspection and preventive maintenance

of your total heating system is important for efficient and safe
operation. Your heating contractor should include humidifier
service at the same time.

All models, except No’s. 448 and 445, are equipped with

an in-line water strainer and orifice as shown below. These parts

should be inspected and cleaned periodically to assure contin­
ued proper unit performance.

OUTVET„

FITTING

SOLErJOlD-

VALVE

IN-LINE

STRAINER

OUTLET
COMPRESSION

NLTT

ORIFICE

(AJI Mod^s

— Except 445)

Inspection and

Service Instructions

1. Disconnect eiectrical power to the furnace

and shut off water supply.

2. Disconnect the water line at the inlet com­

pression nut.

3. Remove the in-line strainer from inside the

inlet fitting by using a small nai! or wire.

4. Flush the in-line strainer clean or replace

with a new strainer, Service Department,
Part No. 4004.

5. Replace the in-line strainer and reconnect

the inlet water line (Double Wrench To
Prevent Leaking}.

6. Disconnect the water line at the outlet com­

pression nut.

7. Remove the orifice from the copper or plas­

tic tube and make sure this small opening is

unplugged.

8. Replace the orifice and reconnect the outlet water line pouble Wrench

To Prevent Leaking).

9. Turn on water supply and reconnect electrical power to the furnace.