Technical Specifications: ECP1

The following technical data were measured on randomized test objects and were typical
data. All measurements are made with the following equipment:
Distortion analyzer:

Tektronix M50 1

Oscilloscope:

Tektronix 468

Oscillator:

Tektronix 5G505

Frequency counter:

Rascal 9838

Phase meter:

Hewlett Packard 3575A

Phono stage
Phono input to record output
Gain 1 KHz Moving Coil (source impedance = 10 ohm)

73 dB (4500x)

Gain 1 KHz Moving Magnet

34.8 dB (55x)

Input Impedance Moving Magnet

47 Kohm/22pF

THD 1 KHz (2V output)

less than 0.007%

Overload 1 KHz Moving Coil (THD = 0,2%)

more than 2 mV

Overload 1 KHz Moving Magnet )THD = 0,2%)

more than 165mV

Channel separation )iV output at 1 KHz)

more than 80dB

Noise ref. 0,5 mV) Moving Coil

-88 dB

Noise (ref. 5 mV) Moving Magnet

-88 dB

Equivalent input noise 400 Hz - 300 KHz)

0,2 uV

RIM Accuracy (20 Hz - 20 KHz)

+/-0,1 dB

Output impedance

100 ohm

Dimensions
Width

240mm (9.5 inches)

Depth

165 mm (6.5 inches)

Height

65 mm (2.5 inches)

Weight

2.2 kg (4.4lbs)