Appendix, C 5:4x – Lab.gruppen C Series 5:4X User Manual

Page 42

Advertising
background image

35

C Series C 20:8X, C 10:8X, C 10:4X and C 5:4X Operation Manual rev. 1.1.4

Appendix

C 5:4X

Level

Load

Rated power

Line Current *2)

Watt *1)

Thermal Dissipation

120 VAC

230 VAC

In

Out

Dissipated

BTU/hr

kCal/hr

Standby w. remote Power Off via NomadLink

6

0

6

20

5

Power On, Idling

51

0

51

312

79

Amp

Watt

Pink noise
(1/8)

70 V / Ch.

125

x4

1,7

0,9

176

63

114

387

98

16 Ω / Ch.

125

x4

1,5

0,8

156

63

94

319

80

32 Ω / Bridged

250

x2

100 V / Ch.

250

x2

1,4

0,7

152

63

89

305

77

8 Ω / Ch.

125

x4

1,3

0,7

134

63

72

244

62

16 Ω / Bridged

250

x2

4 Ω / Ch.

125

x4

1,3

0,7

131

63

68

233

59

8 Ω / Bridged

250

x2

2 Ω / Ch.

63

x4

0,9

0,5

94

32

62

213

54

4 Ω / Bridged

126

x2

Pink noise
(1/4)

70 V / Ch.

125

x4

3,0

1,6

330

125

205

700

176

16 Ω / Ch.

125

x4

2,4

1,3

265

125

140

476

120

32 Ω / Bridged

250

x2

100 V / Ch.

250

x2

2,3

1,2

252

125

127

433

109

8 Ω / Ch.

125

x4

2,0

1,1

222

125

97

331

83

16 Ω / Bridged

250

x2

4 Ω / Ch.

125

x4

2,1

1,1

228

125

103

350

88

8 Ω / Bridged

250

x2

2 Ω / Ch.

63

x4

1,3

0,7

139

63

76

260

65

4 Ω / Bridged

126

x2

*1) The amplifi er’s PSU operates as a non-resistive load, so the calculation “Volts x Amps = Watts” would not be correct. Instead, measured and

specifi ed here is what is known as the “Active Power” in the amplifi er providing useful, real-world values of power consumption and heat dissipation.

*2) Current draw fi gures measured at 230 V. 115 V fi gures are 230 V fi gures multiplied by two.

Table 7.4d: C 5:4X Current Draw and Thermal Dissipation specifications