POWER PRODUCTS INC.

27 PAMARON WAY, SUITE E

NOVATO, CA 94949

415-883-6300

CERTIFICATION OF CALIBRATION

BATTERY DISCHARGE CAPACITY TESTER – MODEL: D-5160

APPLICATION:

Discharge capacity testing of 12 and 24 Volt Lead Acid and Nickel Cadmium
aircraft batteries.

Discharge Range: 2 – 62 Amperes.

Amperes:

XX.X Adjustable to +/- 0.1A

DIGITAL DISPLAYS:

Volts:

XX.X

Time:

Hrs. XX Min. XX Sec. XX

0-75 Ampere, 0-30 Volt Variable Power Supply

CALIBRATION

Power Products P/N PS 7530AF used as battery substitute.

PROCEDURE:

Test instruments and shunt compared to the D5160 unit.
Required accuracy +/- 0.2A from pre-set discharge amps.

▪ Powered by battery under test
▪ Automatic Setting to 12 or 24 Volt battery

SPECIFICATIONS:

▪ Push button adjustment for discharge amperes w/ resolution of 0.1 Amps
▪ Selectable end voltage discharge cutoff, 9/18 Volts or 10/20 Volts.
▪ Meter reading accuracy – Voltmeter +/- 0.2 Volts

Ammeter +/- 0.2 Amperes
Timer 1 sec.

Calibrating Test Instruments Used:
 Meters: Fluke 8010A DC MV Digital, Fluke 87 DC Volts Digital

NOTES:

▪ Shunt: EMPRO 100A 100MV 0.25% accuracy
 Traceable to NIST Calibration within one year
 Instrument test before each equipment test and calibration:

Fluke meters with standard cell of 1.019 Volts to +/- 1.02 V

UNIT:

BATTERY DISCHARGE CAPACITY TESTER

MODEL:

D-5160

SERIAL #:

_____________________

DATE OF MANUFACTURE:

_____________________

PROCEDURE:

D5160CAL- 62-01

ENVIRONMENTAL CONDITIONS:

NOMINAL 70º - 80º F 35 - 40% R.H.

SHIPPED CONDITION:

CALIBRATED / IN TOLERANCE_____________________

CALIBRATED BY:

________________ DATE CALIBRATED: _______________

DUE DATE OF NEXT CALIBRATION (ANNUAL):

________________________________________

APPROVED BY_______________________ TITLE:______________________ DATE:_______________

Lamar Technologies certifies that the above listed instrument meets or exceeds all published specifications. It has been calibrated
using standards MIL-I-45208 whose accuracies are traceable to the National Institute of Standards and Technology.