LINK Systems System 1100 Tonnage Monitor User Manual

Page 105

Advertising
background image

ERROR CODES

___________________________________________________________________

Error No.

Message / Action

10-2

strain link on the same dual channel card. Now
swap the strain link connections, plugging the
strain link in error into the adjacent strain
link's socket and vise versa. Turn on power to
the System 1100. If the error code moves to the
swapped channel, then the strain link or strain
link wiring is causing the error and should be
checked. If the error code stays on the same
channel, then the Channel card is at fault and
should be replaced.

005

Channel 1 threshold on too long.

006

Channel 2 threshold on too long.

007

Channel 3 threshold on too long.

008

Channel 4 threshold on too long.

Error codes 005, 006, 007, and 008 indicate that the
output signal of the channel identified by the error
code has stayed above the automatic zeroing
threshold for too long. A fault in the particular
channel card, the input strain link to the channel,
or the strain link wiring will produce threshold
errors. These error codes may also appear if the
machine is stopped under load, or ,if configured for
use with the optional zeroing cam, if the press is
stopped 'off of the cam' (with the zeroing cam
switch open) for extended lengths of time.

To correct these errors follow the same procedure
outlined for error codes 001, 002, 003, and 004.

030

Speed setting error.

This error can be caused by a mal-adjusted speed
setting in the System 1100 configuration menu, or by
attempting to execute Auto Setup while running over
500 SPM using the rate of change zeroing method.

1)

Check the MACH SPEED setting in the Config menu
for correctness (see section 2.8.8).