Quantum, Application guide, 8 analog to digital converter – dbx Pro QUANTUM User Manual

Page 69: Hardware, Software, Quantum user manual

Advertising
background image

®

Application Guide

Section 6

QUANTUM

59

®

QUANTUM User Manual

Hardware

1.

Connect line inputs to QUANTUM’s analog inputs.

2.

Connect the QUANTUM’s AES/EBU or S/PDIF OUTPUT to digital recorder.

Software

1.

Press the UTILITY button to enter the QUANTUM’s utility section. Change the INPUT to
ANALOG.

2.

Change the CLOCK to desired internal sample rate.

3.

Press the NORM/OUTPUT button twice. This accesses the dither and noise shaping of the
output module.

4.

Set QUANTUM to resolution of your recording device 8, 16, 20, or 24-bit.

5.

Choose which type of dither you would like to use (refer to Section 4.16).

6.

Choose which type of noise shaping you would like to use (refer to Section 4.16).

7.

Press the NEXT PAGE button to scroll to next set of options.

8.

Set dither out to All, if you are monitoring the dither.

9.

Press OTHER button to access TYPE IV™ conversion system (refer to Appendix B).

10. Press STORE if you wish to save non-utility changes (refer to Section 3.4)

SHAPE

DITHER

586

Dual Vacuum
Tube Preamp

INSERT

METER SOURCE

DRIVE

dB

-10

+15

+25

(LINE 0dB)

+60

+30

LOW

dB

-15

0

+15

PHASE

LOW CUT

+48V

MID

dB

-15

0

+15

FREQUENCY

dB

100

200

1k

8k

4k

NARROW

HIGH

dB

-15

0

+15

LINE

INSERT

EQ

LEVEL

dB

-15

0

+15

PeakPlus

THRESHOLD

dB

0

+5

+10

Off

+20

+15

PAD

Off: None

Off: None

Green: TPDF Green: Shape 1

Red: SNR2

Red: Shape 2

TYPE IV

CONVERSION SYSTEM

DRIVE

OUTPUT

LIMIT

CLIP

CHANNEL ONE

20

10 7 5 3

0

3

+

-

®

DECIBELS

-15

-20

-10

-25

-5

-30

0

INSERT

METER SOURCE

DRIVE

dB

-10

+15

+25

(LINE 0dB)

+60

+30

LOW

dB

-15

0

+15

PHASE

LOW CUT

+48V

MID

dB

-15

0

+15

FREQUENCY

dB

100

200

1k

8k

4k

NARROW

HIGH

dB

-15

0

+15

LINE

INSERT

EQ

LEVEL

dB

-15

0

+15

PeakPlus

THRESHOLD

dB

0

+5

+10

Off

+20

+15

PAD

DRIVE

OUTPUT

LIMIT

CLIP

CHANNEL TWO

20

10 7 5 3

0

3

+

-

®

DECIBELS

-15

-20

-10

-25

-5

-30

0

6.8 Analog to Digital Converter

Advertising