Schedule I. Periodic inspection log sheet (every 100 hours of operation

)

WINCH SERIAL NUMBER:

(over 600 hours, print more
of these pages at
www.portablewinch.com)

INITIAL

INSPECTION

#1

#2

#3

#4

#5

#6

DATE

HOUR METER READING

YES / NO

GEARBOX

Warning labels present and
legible?

Any leaks found?

Gearbox oil level is OK

All screws and bolts are tight

Anchor hooks - no cracks,
clasp is working

Shaft end-play less than
0.5 mm (0.020'')

Drum keyway is tight

Capstan shaft & seal area are
clean

Rope entry pulley (brass
pulley) rotating, no flat section

Cracks in housing found?

ROPE GRABBING
SYSTEM/WINCH CONTROLS

Main plate pivots freely

Pivot bolt is tight

No excessive wear on pivoting
parts

Throttle control operational

Clutch rotor is tight, no cracks
or uneven wear

Clutch drum is tight, turns
freely, wall is >2 mm

ENGINE

Spark plug is clean with proper
gap

Idle speed is adjusted

Valve clearance within specs

Fuel tank/filter are clean

Spark arrestor is clean

Oil is new and level is good

Air filter is clean

Figure 37

Figure 38