Installation - General Notes

1. Installation should be carried out in accordance

with the current edition of the I.E.E. Wiring

Regulations. It is recommended that installation is

undertaken only by a qualified electrician.

2. The timer should not be mounted on an unearthed

metal or metallised surface.

3. If the timer is to be connected to an appliance that is

required to be earthed the supply earthing conductor

and the appliance earthing conductor should be

terminated together in the earth terminal provided

within the timer.

4. It must be ensured that the brass inter-connecting

link is correctly positioned and retained in the

terminals during connection of the supply conductors

(applicable to types IHT/T and IHT/W).

5. When cutting out the required apertures in the cover

to accommodate the input and output cables/cords it

should be ensured that no sharp edges remain.

6. All terminals are suitable for fixed cables, and for

flexible cables or cords.

7. For stranded wires use ferrules supplied.

Installation Procedure

1. Switch the supply off at the mains. Means of dis-

connection from the supply having at least 3mm

contact separation in all poles must be incorporated

in the fixed wiring mains supply.

2. Loosen screws (a) and separate housing from timer

base. Pull timeswitch module off backplate. Offer

backplate to mounting location and mark fixing

points b, c and d. Drill wall for screw fixings. Fix

backplate to wall. Push timeswitch module onto

backplate, ensuring good engagement of tab

terminals with receptacles.

3. Bare wires for 6mm (1/4 inch) maximum; insert into

terminals and secure with the screws, in accordance

with circuit diagram label beneath terminals.

4. Secure cables/cords with clamp provided and check

all wiring (see figure 4). Note: Mains supply using

fixed wiring does not need to pass through clamp.

5. Cut out cable entries on underside of housing as

necessary to accomodate cables/cords. Please refer

to 5. above.

6. Refit housing to timer base.

7. Switch on mains.

Installation as general purpose timer

If you are not controlling an immersion heater, but

you are still controlling a mains-fed load, please wire

in accordance with “Immersion Heater Connections”

diagram shown in this instruction. If the timer is supplied

by the mains, but you wish to control a circuit which

must be kept electrically separate to the incoming mains

supply, please follow the instructions below.

Removal of the “bridge wire” between terminals 2 and

3 enables the timer to be used as a general purpose

timer, since the switch is then electrically separate from

the mains input to the motor. The switch can then be

used to control a separate circuit. When installing as

a general purpose timer, follow instructions 1. and 2.

above, then slacken screws to terminals 2 and 3 and

remove bridge wire; affix general purpose timer wiring

diagram provided over existing IHT wiring label; wire in

accordance with general purpose diagram, then follow

instructions 4. to 7. above.

Setting up

Rotate minute hand until arrowhead on clock face,

aligns with correct time on outer dial. i. e. 8=8.00

a.m., 18=6.00 p.m. (see figure 1). When setting up

seven day version (IHT/W, GPT/W), align correct time

on outer dial, within current day sector of dial.

Note: Weekdays are printed on dial in abbreviations of

three languages.

Twenty-four hour (IHT/T, GPT/T) minimum switching

time: 15 minutes.

Seven day (IHT/W, GPT/W) minimum switching time:

2 hours.

To set ON/OFF times, move all tappets between

ON and OFF times required to outer position i.e. to

set ON at 8.00 a.m. and OFF at 11.00 a.m. move all

tappets to outer position (see figure 2): Set any other

ON/OFF times in a similar manner.