2. For the Master and Slave, ensure the Azimuth (AZ) and

Elevation (EL) Adjustment Bolts are in the middle of their
adjustment ranges.

Elevation (EL)
Adjustment Bolt

Azimuth (AZ)
Adjustment Bolt

3.

Master

Aim the Master at the Slave. If necessary, adjust

the Master’s position on the pole:

a. Loosen the Hex Nuts.
b. Adjust the Pole Mount Bracket and Pole Clamps.
c. Tighten the Hex Nuts.

Hex Nuts

Master

4.

Slave

Aim the Slave at the Master to achieve the

strongest Signal Strengths for the Slave. If necessary,
adjust the Slave’s position on the pole.

Note:

The Signal Strength bar graphs display the

absolute power level (in dBm) of the received
signal for each chain. Lower values indicate
stronger received signal levels.

5.

Master

Adjust the azimuth and elevation of the Master

until the strongest Signal Strengths are displayed for
the Master.

a. Sweep the Azimuth (AZ) Adjustment Bolt of the Master

through its adjustment range.

Master
Azimuth (AZ)
Adjustment Bolt

b. Sweep the Elevation (EL) Adjustment Bolt of the Master

through its adjustment range.

Master
Elevation (EL)
Adjustment Bolt

Note:

If the Antenna Alignment window displays

“Overload” to indicate overload condition, see ”RX
Gain” on page 24
for more details about RX
Gain
and overload condition.