2 serial interface rs232, 4 communication procedure, Serial interface rs232 – Pilz PNOZ mm0p 24VDC User Manual

Page 78: Communication procedure

Advertising
background image

RS232/Ethernet interfaces

Operating Manual PNOZmulti communication interfaces
1001154-EN-13

78

Ethernet

Hub/Switch

Hub/Switch

Ethernet subscriber

Ethernet subscriber

PNOZmulti base unit

with Ethernet interface

PNOZmulti base unit

with Ethernet interface

PC with PNOZmulti

Configurator

Fig.: PNOZmulti as Ethernet subscriber - possible topologies

Serial interface RS232

The connection between the RS 232 interface on the communications partner and the inte-
grated interface on the base unit is established via a null modem cable.
Transmission rate:

19.2 kBit with

}

8 bits of data

}

1 start bit

}

2 stop bits

}

1 parity bit

}

Even parity

Communication procedure

When communicating via the integrated interface, the PNOZmulti is always the connec-
tion's Server; the communications partner (PC, SPS) is the Client.