Operation, Controller settings, Operation 2.3.1. controller settings – d&b Yi7P User Manual

Page 7

Advertising
background image

2.3. Operation

NOTICE!

Only operate d&b loudspeakers with a correctly configured d&b

amplifier, otherwise there is a risk of damaging the loudspeaker

components.

Application

Setup

Cabinets per

channel

Yi7P

Y7P

2

Yi10P

Y10P

2

For applicable amplifiers, the controller setups are available in

Dual Channel and Mix TOP/SUB mode.

2.3.1. Controller settings

For acoustic adjustment the functions CUT, HFA and CPL can be

selected.

CUT circuit
Set to CUT, the cabinet low frequency level is reduced. The

cabinets are now configured for use with actively driven d&b

subwoofers.

HFA circuit
In HFA mode (High Frequency Attenuation), the HF response of the

system is rolled off. HFA provides a natural, balanced frequency

response when a unit is placed close to listeners in near field or

delay use.

High Frequency Attenuation begins gradually at 1 kHz, dropping

by approximately 3 dB at 10 kHz. This roll off mimics the decline

in frequency response experienced when listening to a system from

a distance in a typically reverberant room or auditorium.

CPL circuit
The CPL (Coupling) circuit compensates for coupling effects

between the cabinet and close boundary surfaces. CPL begins

gradually around 1 kHz, with the maximum attenuation below

400 Hz. To achieve a balanced frequency response, the CPL

circuit can be set to dB attenuation values between 0 and –9.

Positive CPL values create an adjustable low frequency boost (0 to

+5 dB) at around 65 Hz and can be set when the system is used in

full range mode without subwoofers.

-5

0

5

10

-10

-15

-20

-25

-30

20

100

1k

10k

20k

Frequency response correction of HFA circuit

Frequency response correction of CPL circuit

d&b Yi7P/Yi10P Manual 1.1 en