Seer, Cooling performance with evaporator coils, 2hp13 split system heat pump – Ducane (HVAC) 2HP13 User Manual

Page 3

Advertising
background image

2HP13 Split System Heat Pump

2HP13 Split System Heat Pump

seer

13

seer

13

Cooling Performance with Evaporator Coils

Outdoor

Model

Indoor Model

Cooling

Heating

Refrigerant

Connection

Indoor

Metering

Device

Piston or Field

Installed TXV

Factory

Installed TXV

Outdoor

Indoor

Suction

Liquid

Req'd

Indoor

2

Orifice

Optional

Field

Installed

Orifice

SEER

EER

Rated

ARI

Capacity

1

Rated

Sensible

Capacity

HSPF

47°

17°

CFM

Suction

Liquid

Suction

Liquid

Btuh

COP

Btuh

COP

2HP13**18P

E(C,H,M,U)1P36(A,B,C)+TXV

E(C,H,M,U)2T36(A,B,C)

13.00

12.00

19,000

15,000

7.70

18,000

2.88

11,900

1.84

650

3/4

3/8

3/4

3/8

3/4

3/8

---

H2TXV01

2HP13**24P

E(C,H,M,U)1P29A+TXV

E(C,H,M,U)2T29A

13.00

11.50

24,000

19,700

7.70

22,000

2.88

13,400

2.18

850

3/4

3/8

3/4

3/8

3/4

3/8

---

H2TXV01

E(C,H,M,U)1P36(A,B,C)+TXV

E(C,H,M,U)2T36(A,B,C)

13.00

11.50

24,400

19,700

7.70

22,600

2.88

13,400

2.22

850

3/4

3/8

3/4

3/8

3/4

3/8

---

H2TXV01

2HP13**30P

E(C,H,M,U)1P36(A,B,C)+TXV

E(C,H,M,U)2T36(A,B,C)

13.00

11.00

29,000

23,800

7.70

25,800

3.30

15,900

2.14

1085

3/4

3/8

3/4

3/8

3/4

3/8

---

H2TXV01

2HP13**36P

E(C,H,M,U)1P43B

E(C,H,M,U)2T43B

13.00

11.00

35,000

25,800

7.70

35,000

3.00

21,800

2.04

1250

3/4

3/8

7/8

3/8

3/4

3/8

.076

H2TXV01

E(C,H,U)1P49C

E(C,H,U)2T49C

13.00

11.00

35,000

25,800

7.70

35,000

3.00

21,800

2.04

1250

3/4

3/8

7/8

3/8

3/4

3/8

.076

H2TXV01

2HP13*42P

E(C,H,U)1P49C

E(C,H,U)2T49C

13.00

12.00

40,000

30,000

7.70

38,000

3.06

21,800

2.38

1450

7/8

3/8

7/8

3/8

7/8

3/8

.076

H2TXV02

E(C,U)1P60D

E(C,U)2T60D

13.00

12.00

40,000

30,000

7.70

38,000

3.06

22,000

2.38

1450

7/8

3/8

7/8

3/8

7/8

3/8

.076

H2TXV02

EH1P49D

---

13.00

12.00

40,000

30,000

7.70

38,000

3.06

21,800

2.38

1450

7/8

3/8

7/8

3/8

7/8

3/8

.076

H2TXV02

2HP13*48P

E(C,H,U)1P49C

E(C,H,U)2T49C

13.00

11.50

46,000

34,500

7.70

45,000

2.96

29,400

2.28

1650

7/8

3/8

7/8

3/8

7/8

3/8

.082

H2TXV02

E(C,H,U)1P62D

E(C,H,U)2T62D

13.00

11.50

46,500

35,000

7.70

45,500

2.96

30,000

2.32

1650

7/8

3/8

7/8

3/8

7/8

3/8

.082

H2TXV02

2HP13*60P

E(C,H,U)1P62C

E(C,H,U)2T62C

13.00

11.50

56,000

40,900

7.70

54,000

3.40

32.000

2.58

1950

7/8

3/8

7/8

3/8

1-1/8

3/8

.098

H2TXV02

E(C,H,U)1P62D

E(C,H,U)2T62D

13.00

11.50

54,000

39,400

7.70

52,000

3.40

31,600

2.54

1950

7/8

3/8

7/8

3/8

1-1/8

3/8

.098

H2TXV02

1

Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.

2

Required to achieve ARI rating.

A blower time delay is required to achieve ARI rating.

** - B, L, BC, LC
* - B, L

Advertising