Dell R510 User Manual

Page 81

Advertising
background image

Dell

81

PowerEdge R510 Technical Guide

How is this memory write
protected?

How is the memory cleared?

iDRAC6 SDRAM

n/a

AC cycle for BMC OS and reset/power off server for VGA frame
buffer

iDRAC6 FRU

writes controlled by iDRAC
embedded OS

EPPID is not clearable

iDRAC6 Boot Block
Flash

iDRAC embedded OS
control of the write
protection.

Not possible with any utilities or applications and iDRAC does not
function as expected if corrupted/removed. Lifecycle log is
clearable only in a factory environment.
SEL is user-clearable

Trusted Platform
Module

SW write protected

F2 Setup option

Chipset

CMOS

N/A - BIOS only control

Planar NVRAM_CLR jumper or Remove AC cord, remove cover,
remove coin cell battery. Wait for 30 seconds, replace battery,
cover and then AC cord.
F2 system setup option to restore defaults

Backplane (X8)

Storage Controller
Processor

Embedded firmware only
writeable through
controlled iDRAC methods

Not possible with any utilities or applications and backplane does
not function as expected if corrupted/removed.

Control Panel

Internal USB

OS control

OS control format

Power Supply

PSU Microcontroller

Protected by the
embedded
microcontroller. Special
keys are used by special
vendor-provided utilities
to unlock the ROM with
various CRC checks during
load.

N/A - not in system clearable

PDB Microcontroller

Unprotected

N/A - not in system clearable

PERC 6/i Adapter

PERC NVSRAM Config
Data

Storage controller
firmware accessed only

N/A - not in system clearable

PERC firmware

Write control access by
Storage Controller
firmware

N/A - not in system clearable

PERC Cache RAM

Storage controller
firmware accessed only

Storage controller firmware clearable only. Remove AC AND
deplete or remove backup battery.

Advertising