**) If this status code keeps recurring, contact your system engineer.

Status codes –
Class 6

Some of the class 6 status codes necessitate intervention by a Fronius-trained service en-
gineer.

*) If the status code is displayed all the time: Notify a Fronius-trained service engineer.

**) Fault is rectified automatically. If this status code keeps recurring, contact your system
engineer.

Status codes –
Class 7

Class 7 status codes relate to the control system, the configuration and inverter data re-
cording, and may directly or indirectly affect the process of feeding energy into the grid.

Code

Description

Behaviour

Remedy

601

CAN bus is full

The inverter is not feeding
any energy into the grid.

Update inverter firm-
ware; *)

603

DC module temperature sensor faulty

The inverter will automati-
cally attempt to connect
again and, if possible, will
resume feeding energy into
the grid.

*)

608

Functional incompatibility (one or more
PC boards in the inverter are not com-
patible with each other, e.g. after a PC
board has been replaced)

The inverter is not feeding
any energy into the grid.

Update inverter firm-
ware; *)

Code

Description

Behaviour

Remedy

701 -
715

Provides information about the
internal processor status

Warning message on the
display

*)

721

EEPROM has been re-initial-
ised

Warning message on the
display

Acknowledge status code; *)

722 -
730

Provides information about the
internal processor status

Warning message on the
display

*)

746

Error occurred during update
process

Warning message on the
display, update process is
interrupted

Wait for 2 minutes, then start the
update again; *)

751

Time lost

Warning message on the
display

Reset time and date on the invert-
er; *)

752

Real Time Clock module com-
munication error

753

Internal error: Real Time Clock
module is in emergency mode

Time may be inaccurate or
lost (feeding energy into the
grid normal)

Reset time and date on the invert-
er

754 -
755

Provides information about the
internal processor status

Warning message on the
display

*)

757

Hardware error in the Real
Time Clock module

Error message on the dis-
play; the inverter is not feed-
ing any energy into the grid

*)

758

Internal error: Real Time Clock
module is in emergency mode

Time may be inaccurate or
lost (feeding energy into the
grid normal)

Reset time and date on the invert-
er

760

Internal hardware error

Error message on the dis-
play

*)

Advertising