Charge the battery – Fronius Acctiva 12-20 User Manual

Page 32

Advertising
background image

4

Charge the battery

General remarks

CAUTION! Risk of damage when attempting to charge a faulty battery. Before
charging, ensure that the battery to be charged is fully functional.

Important! Parallel operation of consumers (car radio, etc.) is possible during the
charging process. Parallel operation of consumers may lengthen the charging time. If
the power consumed is greater than the maximum available charging current, the battery
may be drained. Ensure that the power used for additional consumers is less than the
maximum available charging current (see Technical Data).

Selecting the
mode

CAUTION! Risk of damage if mode is changed during charging. Disconnect
the charger from the mains and battery before changing the mode.

Fig. 4 Changing to a different mode

(1)

Middle switch position - „wet“ mode

For charging liquid (Pb, Ca, Ca silver) or fixed (GEL, AGM, MF, sealant) electro-
lyte batteries that are used in starter or traction applications.

Important! The mode selector switch is
located approx. 10 mm behind the ventila-
tion slots on the right-hand side panel.
Only operate the mode selector switch
using a suitable screwdriver (D = 2.5 mm
or less).

(1) Mode selector switch

Upper switch position - „GEL“ mode

For charging liquid (Pb, Ca, Ca silver) or fixed (GEL, AGM, MF, sealant) electro-
lyte batteries that are used in standby applications (e.g. emergency power
systems) or at temperatures above 35°C (95° F).

Lower switch position - external power supply/reactivating deep-discharge
batteries

- For external power supply to consumers
- For reactivating deep-discharge batteries

Advertising