General remarks

Set parameters as follows in the Setup menu:
-

Select synergic line type according to the battery to be charged

-

Select node address for FireCAN

Set the synergic
line type option

Connect mains cable to charger and plug into mains

-

Charger in open circuit - ready indicator lights up

Press and hold Start/Stop button for approx. 10 s to retrieve the synergic line setting

-

Ready indicator goes off, and the charger enters setup mode for synergic line type

-

The display also shows the selected synergic line type, e.g. synergic line 1:

Press Start/Stop button to select the synergic line type according to the leaflet

-

If there is no further selection within 10 seconds, the selected synergic line type is
saved.

-

Ready indicator lights up. Once the new synergic line type has been selected, the
charger is ready for the next charging sequence.

IMPORTANT! The Setup menu is only enabled when there is no battery connected to the
charger.

1

2

3

IMPORTANT! Do not connect a battery during this 10 second period; if you do, the select-
ed synergic line type will not be saved. Likewise, the setting will not be saved if a power
failure occurs.