Appendix B: Rack Mount Options

CWDM MUX/DEMUX units can be mounted in a 19” rack using the mounting kit

Mounting Instruction Rackmount-Kit 455-8G

Using the Rackmount-Kit 455-8G, up to 4 devices of the device size 103x143x42mm (Dual-
Head Devices) can be mounted into a 19“-Server Rack. The Rackmount Kit requires 1U Rack
space. Blind plates (in the list of parts delivered) allow covering unused device positions.

Rackmount-Kit 455-8G – List of parts delivered:

The CWDM MUX/DEMUX units require the rack space of two regular
devices. So far you can mount up to 2 CWDM MUX/DEMUX units into a
1U rack space.

Mounting instruction:

Align the holes on the base plate with the vacant screw holes on the base of the device.

Fasten the base of the unit to the plate of the mounting kit

Only use the supplied, short screws, to prevent damages on
the PCB’s

Close the remaining gaps with blanking plates.

base plate

8 pieces spacer – M2,5x2

8 pieces M2,5x5 Philips type
countersunk screws

3 pieces blind plate