Operation and configuration – Ivoclar Vivadent EP 5010 User Manual
Page 50
 
50
The following parameters can be changed in the Settings menu:
Temperature unit
Choose between °C and °F.
Setting options: °C / °F
Vacuum unit
Choose between mbar and hPa.
Setting options: mbar and hPa
Vacuum quality 
Set the final vacuum value. This value defines the negative pressure in the furnace head at which the 
furnace has reached a vacuum quality of 100%.
Setting options: 0 – 200 mbar
Language 
Select the desired operating language.
Setting options: German, English, Italian, French, Spanish, Portuguese, Swedish, Dutch, Turkish, Russian, 
Polish, Croatian, Traditional Chinese, Mandarin Chinese, Finnish, Norwegian, Slovenian, Czech, Slovakian, 
Hungarian, Hindi, Japanese, Korean, Arabic, Farsi
Volume
Select the desired volume of the acoustic signals.
Setting options: Off / 20 – 100% in 10%-steps
Melody
Select the desired melody for the acoustic signals.
Setting options: Melody 1 to 20
Time
Set the current time.
Setting options: hh:mm:ss
Date
Set the current date.
Setting options: according to the set date format
Date format
Set the date format.
Setting options: dd:mm:yyyy; mm:dd:yyyy
Automatic power-saving mode
If the power-saving mode is activated and the furnace head closed, this function is automatically started 
after 30 minutes, provided the furnace is in idle mode and no key is pressed during that time. 
The display shows the power-saving icon. Pressing any key ends the automatically activated power-saving 
function. The power-saving mode is not available in the press operating mode.
Setting options: On / Off
Optical Status Display (OSD)
The OSD can be switched on or off.
Setting options: Off / On 10 – 100% in 10%-steps
Display brightness
Set the display brightness.
Setting options: 20 – 100% in 10%-steps
User code
The user code can be individually changed.
It is recommended to make a note of the individually changed user code and to keep it
separately. If forgotten, the user code may only be reset with the help of the After Sales Service.
Setting options: 1000 to 9999
5. Operation and Configuration