Installation Instructions/Instrucciones de Instalación

1. Determine the location of the valve making sure that the

center line of the valve is located 1 3/4 - 3 1/4” from the surface

of the finished wall.

2. Once proper location is determined, install supportive framing

to mount valve to using included screws.

3. Install NPT threaded copper adapters to the inlet & outlets,

applying teflon tape to all threaded connections.

Then solder copper piping onto adapters and run to

designated water supply or outlet.

Important! Take the following precautions if soldering copper

piping directly onto valve:

a.) Remove ALL components from the valve prior to soldering,

including plaster guards & cartridges.

b.) Wrap valve body with cold rag before soldering. Take

special care not to overheat brass rough-in.

c.) Use copper piping only, do not attempt to solder steel

piping to valve.

d.) Reinstall all components after soldering.

4. Make sure all functions are plugged or in the off position.

Then turn water on and bleed air from lines. Inspect all piping

for leaks. Make sure to inspect complete system by diverting

water to all functions.

5. Finish the surrounding wall. To ensure proper fit, do not over-

size the hole - use the plaster guard as a guide for correct

diameter.

6. Remove the plaster guard once the finished wall is complete.