Legrand TITAN Series v.2 User Manual

Titan, Installation instructions, Package contents

Advertising
background image

TITAN

INSTALLATION INSTRUCTIONS

INCANDESCENT DIMMERS, MAGNETIC LOW VOLTAGE DIMMERS,

FAN SPEED CONTROLS, DEHUMMER FAN SPEED CONTROLS,

FLUORESCENT DIMMERS

P/N 340872

INCANDESCENT DIMMERS “CD” SERIES: These dimmers are for use with

Incandescent and Halogen lamps.
CAUTION: To reduce the risk of overheating and possible damage to other

equipment, do not install to control a receptacle, a fluorescent light, a motor-

operated appliance, or a transformer supplied appliance.
• Do not use this dimmer with incandescent lamps whose power require-

ments exceed maximum power (stated in Watts) of this control.

• Do not connect this dimmer to power source other than 120VAC, 60 Hz only.

• Use copper wire only.
MAGNETIC LOW VOLTAGE DIMMERS “CDLV” SERIES: These dimmers are for

use with Magnetic Low Voltage Incandescent and Halogen lamps.
CAUTION: To reduce the risk of overheating and possible damage to other

equipment, do not install to control a receptacle, a fluorescent light, or a

motor-operated appliance. Connect only in a 120VAC, 60 Hz circuit to control

the primary winding of a transformer supplied incandescent and halogen

lamp. The maximum VA rating of this dimmer applies to the transformer

input, not the load on the transformer secondary.
• Do not use to control a solid state electronic low voltage transformer.

• Do not use with inoperative or missing lamps. Use of this dimmer with

inoperative or missing lamps can create an over current condition which

may damage the transformer. Use transformers that incorporate thermal

protection or a fuse at the primary windings.

• Use copper wire only.
FAN SPEED CONTROLS “CDSC” SERIES: These controls are for use with

ceiling paddle fans with split-capacitor or shaded pole motors only. Use only

with ceiling paddle fans that are marked “Suitable for Use with Solid State

Fan Speed Controls.” Set multi-speed fans to their highest setting before

installing this control.
• Multiple ceiling paddle fans of the same type may be used if the maximum

power (stated in Amps) of this control is not exceeded.

• Do not connect this control to power source other than 120VAC, 60 Hz only.

• Use copper wire only.

• This control is intended for installation in either a metal outlet box or a

polymeric (plastic) outlet box.

DEHUMMER FAN SPEED CONTROLS “CDDH” SERIES: These controls are for

use with a single ceiling paddle fan only.
• Do not use this control with a ceiling paddle fan that exceeds the maximum

power (stated in Amps) of this control.

• Do not connect this control to power source other than 120VAC, 60 Hz only.

• Use copper wire only.
FLUORESCENT DIMMERS “CDFB” SERIES: These dimmers are for use with

electronic dimming ballasts that utilize 2-wire control (see TABLE 1 below):
• Use copper wire only.

FLUORESCENT DIMMERS “CD3FB” SERIES: These dimmers are for use with

electronic dimming ballasts that utilize 3-wire control (see TABLE 2 below):
• Use with Lutron FDB or ECO series Electronic Fluorescent Dimming

Ballasts only. Do not use with any other ballasts.

• Use copper wire only.

PACKAGE CONTENTS

One of the following Dimmers:

Narrow Dimmers

Wide Dimmers

Cat no.:

Cat no.:

Cat no.:

Cat no.:

CD700

CD703P

CD1600

CD1603P

CD1100

CD1103P

CD2000

CD2003P

CDLV700

CDLV703P

CDLV1600

CDLV1603P

CDLV1100

CDLV1103P

CDFB10

CDFB103P

CDFB5

CDFB53P

CDFB16

CDFB163P

CDFB8

CDFB83P

CDFB7-277

CDFB73P-277

CDSC6

CD3FB163P

CDFB10-277

CDFB103P-277

CDDH16

CD3FB103P-277

CDSC12

CD3FB16

CD3FB10-277

Wire Nuts

Coupler

Small Coupler

Wall Plate

WALL PLATE LABELING SYSTEM

(for use with wall plate that contains label holding slot)

These dimmer wall plates contain a label holding slot. A

0.33" x 1.5" label can be placed in this label holding slot.

These labels can be printed from an Avery

®

standard

template: Divider tab inserts 8-Tabs or equivalent.
Install the label with the following procedure:
1. Disconnect power to the circuit by removing fuse or

turning circuit breakers OFF.

2. Remove the wall plate by

placing a small flat head

screwdriver into one of

the four slots located at

the top and bottom of the

wall plate. Gently twist a

half turn until the plate

pops off.

3. Slide the label in from the

back side of the wall plate

(as shown at right).

Compatible

P&S Cat #

CDFB5
CDFB8

CDFB53P
CDFB83P

CDFB10
CDFB16

CDFB103P
CDFB163P

CDFB7-277

CDFB10-277

CDFB73P-277

CDFB103P-277

Model

REZ-132-SC, REZ-2S32-SC, REZ-3S32-SC, REZ-154, REZ-2S54,
REZ-1Q18-M2, REZ-2Q18-M2, REZ-1T42-M2, REZ-2T42-M3,
REZ-1TTS40/REZ-1TTS40-SC, REZ-2TTS40/REZ-2TTS40-SC,
IEZ-2S24-D, REB-2S26-M1-LS-DIM/REB-2S26-M1-BS-DIM

2W-T426-120-1-S, 2W-T426-120-2-S, 2W-T432-120-1-S,
2W-T432-120-2-S, 2W-T832-120-1-S, 2W-T832-120-2-S

QTP1x32T8/UNV DIM, QTP2x32T8/UNV DIM, QTP3x32T8/UNV
DIM, QTP4x32T8/UNV DIM

VEZ-132-SC, VEZ-2S32-SC, VEZ-3S32-SC, VEZ-154, VEZ-2S54,
VEZ-1Q18-M2, VEZ-2Q18-M2, VEZ-1T42-M2, VEZ-2T42-M3,
VEZ-1TTS40/VEZ-1TTS40-SC, VEZ-2TTS40/VEZ-2TTS40-SC,
IEZ-2S24-D

QTP1x32T8/UNV DIM, QTP2x32T8/UNV DIM, QTP3x32T8/UNV
DIM, QTP4x32T8/UNV DIM

Voltage

120VAC

60 HZ

277VAC

60 HZ

Ballast

Manufacturer

Advance

Lutron

Sylvania/

Osram

Advance

Sylvania/

Osram

CD3FB16

CD3FB163P

CD3FB10-277

CD3FB103P-277

120VAC

60 HZ

277VAC

60 HZ

Lutron

Lutron

FDB-T418-120-1-S, FDB-T418-120-2-S,
FDB-T426-120-1-S, FDB-T426-120-2-S,
FDB-T418-120-1-S, FDB-T418-120-2-S,
FDB-T426-120-1-S, FDB-T426-120-2-S,
FDB-T432-120-1-S, FDB-T432-120-2-S,
FDB-T442-120-1-S, FDB-T442-120-2-S,
FDB-1643-120-1, FDB-1643-120-2,
FDB-1643-120-3, FDB-2227-120-1,
FDB-2227-120-2, FDB-2227-120-3,
FDB-2243-120-1, FDB-2243-120-2

FDB-T418-277-1-S, FDB-T418-277-2-S,
FDB-T426-277-1-S, FDB-T426-277-2-S,
FDB-T418-277-1-S, FDB-T418-277-2-S,
FDB-T426-277-1-S, FDB-T426-277-2-S,
FDB-T432-277-1-S, FDB-T432-277-2-S,
FDB-T442-277-1-S, FDB-T442-277-2-S,
FDB-1643-277-1, FDB-1643-277-2,
FDB-1643-277-3, FDB-2227-277-1,
FDB-2227-277-2, FDB-2227-277-3,
FDB-2243-277-1, FDB-2243-277-2

HL3-T426-120-1-S, HL3-T432-120-1-S,
FDB-T524-120-1, FDB-T524-120-2,
FDB-T539-120-1, FDB-T539-120-2,
FDB-T554-120-1, FDB-T554-120-2,
FDB-2427-120-1, FDB-2427-120-2,
FDB-2427-120-3, FDB-3627-120-1,
FDB-3627-120-2, FDB-3627-120-3,
FDB-4827-120-1, FDB-4827-120-2,
FDB-4827-120-3, FDB-6027-120-1,
FDB-6027-120-2, FDB-7280-120-1,
FDB-8480-120-1, FDB-9680-120-1,

H3DT832CUNV110, H3DT832CUNV117,
H3DT832CUNV210, H3DT832CUNV217

HL3-T426-277-1-S, HL3-T432-277-1-S,
FDB-T524-277-1, FDB-T524-277-2,
FDB-T539-277-1, FDB-T539-277-2,
FDB-T554-277-1, FDB-T554-277-2,
FDB-2427-277-1, FDB-2427-277-2,
FDB-2427-277-3, FDB-3627-277-1,
FDB-3627-277-2, FDB-3627-277-3,
FDB-4827-277-1, FDB-4827-277-2,
FDB-4827-277-3, FDB-6027-277-1,
FDB-6027-277-2,

H3DT832CUNV110,

H3DT832CUNV117, H3DT832CUNV210,
H3DT832CUNV217

P&S

Cat. #

Voltage

Ballast

Manufacturer

1% – Hi-lume, Hi-lume 3D

Model

5% – Compact SE

10% – Eco-10

Table 1

Table 2

E3-T514C-120-1, E3-T514C-120-2,
E3-T521C-120-1, E3-T521C-120-2,
ECO-T528-120-1, ECO-T528-120-2,
ECO-T524-120-1, ECO-T524-120-2,
ECO-T5H39-120-1, ECO-T5H39-120-2,
ECO-T554-120-1, ECO-T554-120-2,
ECO-T539-120-1, ECO-T539-120-2,
ECO-T539-120-3, ECO-T540-120-1,
ECO-T540-120-2, ECO-T540-120-3,
ECO-T550-120-1, ECO-T550-120-2,
ECO-T817-120-1, ECO-T817-120-2,
ECO-T817-120-3, ECO-T825-120-1,
ECO-T825-120-2, ECO-T832-120-1-L,
ECO-T832-120-1-T, ECO-T832-120-2-L,
ECO-T832-120-2-T, ECO-T832-120-3

E3-T514C-277-1, E3-T514C-277-2,
E3-T521C-277-1, E3-T521C-277-2,
ECO-T528-277-1, ECO-T528-277-2,
ECO-T524-277-1, ECO-T524-277-2,
ECO-T5H39-277-1, ECO-T5H39-277-2,
ECO-T554-277-1, ECO-T554-277-2,
ECO-T539-277-1, ECO-T539-277-2,
ECO-T539-277-3, ECO-T540-277-1,
ECO-T540-277-2, ECO-T540-277-3,
ECO-T550-277-1, ECO-T550-277-2,
ECO-T817-277-1, ECO-T817-277-2,
ECO-T817-277-3, ECO-T825-277-1,
ECO-T825-277-2,

E3-T832C-277-1,

ECO-T832-277-1-L, ECO-T832-277-1-T,
ECO-T832-277-1, E3-T832C-277-2

,

ECO-T832-277-2-L, ECO-T832-277-2-T,
ECO-T832-277-2, ECO-T832-277-3

Advertising
This manual is related to the following products: