Diagnostic messages – Dynasty Spas GS500 User Manual

Page 2

Advertising
background image

P/N 40299 05/28/2004

Warning! Shock Hazard! No User Serviceable Parts.

Do not attempt service of this control system. Contact your dealer or service organization for assistance. Follow all owner’s manual power
connection instructions. Installation must be performed by a licensed electrician and all grounding connections must be properly installed.

Message

No message on display.

Power has been cut off to the spa.

Temperature unknown.

“Overheat” - The spa has shut down. One of the
sensors has detected 118°F/48°C at the heater.

“Overheat” - The spa has shut down. One of

the sensors has detected that the spa water is

110°F/43°C.

“Ice” - Potential freeze condition detected.

Spa is shut down. The sensor that is plugged into

the Sensor “A” jack is not working.

Spa is shut down. The sensor that is plugged into

the Sensor “B” jack is not working.

Sensors are out of balance. If alternating with

spa temperature, it may just be a temporary

condition. If flashing by itself, spa is shut down.

A significant difference between temperature

sensors has been detected. This could indicate a

flow problem.

Persistent low flow problems. (Displays on the

fifth occurrence of “ ” message within 24 hours.)

Heater is shut down, but other spa functions

continue to run normally.

Possible inadequate water, poor flow, or air

bubbles in detected in the heater. Spa is shut

down for 15 minutes.

Inadequate water detected in heater. (Displays on

third occurrence of “ ” message.) Spa is

shut down.

The control panel will be disabled until power returns. Spa

settings will be preserved until next power up.

After the circ pump has been running for 2 minutes, the

temperature will be displayed.

DO NOT ENTER THE WATER. Remove the spa cover

and allow water to cool. Once the heater has cooled, reset by

pushing any button. If spa does not reset, shut off the power to

the spa and call your dealer or service organization.

DO NOT ENTER THE WATER. Remove the spa cover

and allow water to cool. At 107°F/42°C, the spa should

automatically reset. If spa does not reset, shut off the power to

the spa and call your dealer or service organization.

No action required. The pump and blower will automatically

activate regardless of spa status.

If the problem persists, contact your dealer or service

organization. (May appear temporarily in an overheat situation

and disappear when the heater cools.)

If the problem persists, contact your dealer or service

organization. (May appear temporarily in an overheat situation

and disappear when the heater cools.)

If the problem persists, contact your dealer or service

organization.

Check water level in spa. Refill if necessary. If the water level

is okay, make sure the pumps have been primed. If problem

persists, contact your dealer or service organization.

Follow action required for “ ” message. Heating capability of

the spa will not reset automatically; you may press any button

to reset.

Check water level in spa. Refill if necessary. If water level is

okay, make sure the pumps have been primed. Press any button

to reset, or this message will automatically reset within

15 minutes. If problem persists, contact your dealer or service

organization.

Follow action required for “ ” message. Spa will not

automatically reset. Press any button to reset.

Meaning

Action Required

Diagnostic Messages